![OKIDATA OL400 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/okidata/ol400/ol400_service-manual_3697857076.webp)
Page: 61
Service Guide OL400
Chapter 3 Maintenance & Disassembly
3.3.03 Modified Page Count
General Information
The modified page counter combines the main motor revolution time and the number of printed
sheets. Drum replacement is determined by the modified page count.
Procedure
To check the modified page count, follow this procedure.
NOTE:
To access the Modified Page Count, you must first view the Actual Page Count.
1.
After viewing the Actual Page Count, press Switch 1 for five seconds. The LED
will
display the contents of the Parameter 1 (Modified Page Count) register.
2.
To end this procedure, press Switch 1 for 1 second. The LED will perform one
short flash to indicate Parameter 1 is selected.
Example
Modified Page Counter = 142
The next step in this table is also the last step in the Actual Page Counter Table
Switch 1 Action
LED Display
Description
Press for 5 seconds
Long Flash
Start of Modified Page Count
None
On-Off-Pause
1st Digit = 1
None
On-Off-On-Off-On-Off-On-Pause
2nd Digit = 4
None
On-Off-On-Off-Pause
3rd Digit = 2
None
Long Flash
Start of Count
Press for 1 second
Flashes ON/OFF
Parameter #1 - Selected
NOTE:
The number "0" is represented by 10 flashes
The Actual and Modified Page Counters CANNOT be changed.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)