
Page: 50
Service Guide ML320/ML321
Chapter 3 Maintenance & Disassembly
3.2.08 Transformer
Revs A and B
NOTE:
The transformer contains a built-in temperature fuse. Once the fuse opens, the transformer
MUST be replaced.
The Rev A, B, and C transformers are NOT compatible with the Rev D transformer.
The transformer shown in the diagram is the Rev A and B transformer. This unit has been
replaced by the Rev C unit, shown on the following pages.
Perform these procedures first:
- 3.2.01 (
)
- 3.2.04 (
)
- Disconnect the cable (1) from the filter assembly.
- Disconnect the cable (2) from the power supply board.
- Remove the screw (3) and detach the grounding wire (4).
- Insert a straight-slot screwdriver into the chassis from the bottom.
(5 shows location)
- Push the lock spring (6) on the transformer and detach the lock spring from transformer
clamp A (7).
- Lift the A side of the transformer and detach it from the transformer clamp B (8).
Содержание ML320 Turbo
Страница 37: ......
Страница 46: ...Page 30 Service Guide ML320 ML321 Chapter 2 Principles of Operation 2 4 MECHANICAL PRINCIPLES OF OPERATION...
Страница 53: ......
Страница 190: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 244: ...Partner Exchange BPX for any updates to this material http bpx okidata com...