Blinking
O
N
External RAM Error
Replace the control
board
Blinking
O
N
Spacing<R>Error
Go to RAP 02 (
)
Blinking
ON
Serial Interface
Error
Replace the Serial
Interface Board
Fault Alarm Conditions - Rev D
MEN
U
Lamp
Statu
s
ALARM
Lamp
Status
SELEC
TLamp
Status
10
12
17
20
PR
OP
UT
L
Error
Conditio
n
Action
Curre
nt<R>
Mode
ON
Curre
nt
CPI
" "
" "
" "
" "
" "
Paper
Out
Add paper
Blinki
ng
ON
Curre
nt
CPI
" "
" "
" "
" "
" "
Printhead
Temp
Normal
Blinking
ON
Internal
RAM
Error
Replace the
control
board
Blinking
ON
Program
ROM
Error
Replace the
ROM.<R>R
eplace the
control
board
Blinking
ON
External
RAM
Error
Replace the
control
board
Blinking
ON
Spacing
Error
Go to
RAP 02 (
)
Blinking
ON
Serial
Interface
Error
Replace the
Serial
Interface
Board
Blinking
ON
EEPROM
error
Replace the
EEPROM
CAUTION:
Check the contacts between the power interconnect module, the control board,
and the power supply board (Rev A and B units ONLY). Clean the contacts with if dirty.
If contacts are bent or broken, replace the module. Proper inspection and cleaning of the
power interconnect module contacts can eliminate a false diagnosis of a failed control
Содержание ML320 Turbo
Страница 37: ......
Страница 46: ...Page 30 Service Guide ML320 ML321 Chapter 2 Principles of Operation 2 4 MECHANICAL PRINCIPLES OF OPERATION...
Страница 53: ......
Страница 190: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 244: ...Partner Exchange BPX for any updates to this material http bpx okidata com...