2-17
Fusing temperature
1) Warming Up
After the initialization of the printer, warming up of the printer starts and the
Heater Lamp turns ON until the temperature of the Heater Roller reaches
approx. 185 °C.
2) Printing
When the printer obtains the printing command from its controller, the Heater
Roller is maintained at 185 °C.
After printing, the printer turns to standby mode. The fuser kept at low
temperature.
3) Standby mode
The Heater Roller maintained at approx. 100 °C.
4) Sleep mode
In this mode, saving the power.
OKIOFFICE 1200:
Temperature
( F) ( C)
Power ON
Warming up
Time
Printing
Standby mode
180
200
160
356
392
320
Sleep mode
Post card printing only
OKIOFFICE 1600:
Temperature
( F) ( C)
Power ON
Warming up
Time
Printing
Standby mode
190
205
170
374
401
338
Sleep mode
Post card printing only