42114101 Rev.1
29 /
(b)
SP Motor overheat alarm
The voltage of the output SPTEMP signal of the thermistors, one of which is contained
in the SP Motor, is monitored by the A/D port of the MPU to control the voltage.
Mode and print control
Stop
Temp
105
°
C
95
°
C
• When the temperature exceeds 105
°
C, printing will stop.
Mode
1
2
3
PrintSpeed
100%
50% ~ 95%
Stop
Temp
~ 94
°
C
95
°
C ~ 104
°
C