42113901 Rev.2
74 /
Oki Data CONFIDENTIAL
3.3.18 Carriage Shaft
(1)
Remove the printhead (see 3.3.1).
(2)
Remove the upper cover (see 3.3.4 (1) – (5)).
(3)
Remove the driver board (see 3.3.12).
Remove the FG plate (L)
2
.
(4)
Slide the carriage shaft
1
to the left side (in the direction of the arrow) to remove.
(5)
To perform mounting, follow the reverse procedure of removal.
Note on installation:
(1)
After installation, check and adjust the gap between platen and printhead (see 4-1).
2
1
1
Содержание ML421 Series
Страница 1: ...42113901 Rev 2 1 133 Oki Data CONFIDENTIAL ML420 421 PRINTER Maintenance Manual ODA...
Страница 2: ...42113901 Rev 2 2 Oki Data CONFIDENTIAL...
Страница 117: ...42113901 Rev 2 117 Oki Data CONFIDENTIAL Figure B 2 Printer General Assy 6 9 7 1 2 3 11 10 4 5 8...
Страница 122: ...42113901 Rev 2 122 Oki Data CONFIDENTIAL Figure B 4 Carriage Assy 12 9 8 6 14 4 10 7 11 13 3 1...