3.3.15 Power Supply Board (TPW)
(1)
Remove the upper cover (see 3.3.4 (1) – (5)).
(2)
Disconnect two flexible cable
3
from the connector
2
the Power Supply Board
1
.
(3)
Remove the cable
5
from the connector
4
on the Power Supply Board
1
.
(4)
Remove two screws
6
, and remove the Power Supply Board
1
.
(5)
To install, follow the removal steps in the reverse order.
Remark on assembly:
(1)
To mount the Power Supply Board, set the change lever to the top position so that
the Switch Lever
7
will not hooked on the microswitches
8
.
7
8
8
3
6
5
4
1
2
A
Note on installation:
(1)
Make sure that there is not any dust or oil on the connector contact section A. If it
is found, wipe it off by alcohol.