42113901 Rev.2
126 /
Oki Data CONFIDENTIAL
Appendix C
RS-232C SERIAL INTERFACE BOARD (OPTION)
1.
GENERAL
This section describes the operation of the RS-232C Serial Interface board installed in the Printer
as an option using a start-stop synchronization and serial communications circuit. This serial
interface board is capable of transmitting and receiving simultaneously at speeds up to 19,200
bits per second. Two protocols are available: printer Ready/Busy and X-ON/X-OFF modes.
2.
OPERATION DESCRIPTION
2.1
Element Description
(1)
80C51 with MASK ROM
An eight-bit microprocessor controller that controls the following:
(a.) Serial interface protocol and data transfer through a serial port.
(b.) Message buffer.
(c.) Transmission of parallel data to the printer.
(2)
75189
An RS-232C standard line receiver
(3)
75188
An RS-232C standard line driver.
(4)
ROM (No Mount)
A 64Kbit ROM that contains the serial interface control program.
(5)
RAM
A 64Kbit static RAM used as a message buffer.