45372301TH Rev.2
6-13 /
Oki Data CONFIDENTIAL
[CC96] Lever path abnormality
* If [EAF5] occurs two times consecutively, it becomes a [CC96] error.
[CDE0] Paddle HP abnormality
* If [ED15] occurs two times consecutively, it becomes a [CDE0] error.
Classification
Error content
Finisher related service call
Lever path abnormality
Check item
Measures
Lever path home position sensor
• Sensor check (S15)
• Connector check (P7-4)
• Harness check
Lever path motor
• Motor check (M10)
• Connector check (P18-1)
• Harness check
Finisher control PC board
• Board check
• Connector check (J7, J18)
• Harness check
Parts to be replaced
Remark
Lever path home position sensor
Lever path motor
Finisher control PC board
Classification
Error content
Finisher related service call
Paddle HP abnormality
Check item
Measures
Paddle home position sensor
• Sensor check (S3)
• Connector check (P8-4)
• Harness check
Paddle motor
• Motor check (M3)
• Connector check (P5-4)
• Harness check
Finisher control PC board
• Board check
• Connector check (J5, J8)
• Harness check
Parts to be replaced
Remark
Paddle home position sensor
Paddle motor
Finisher control PC board