45850101TH Rev.1
3-34
Oki Data CONFIDENTIAL
3. MAINTENANCE MENUS
3.4.9
Print counter display
The print counter display is used for viewing print counter values.
1. Enter the self-diagnostic mode and, until PRINTER STATUS appears, press the
[2]
or
[8]
button (the
[2]
button displays the next test option and the
[8]
button
displays the preceding test option). Then press the
[6]
button.
2. Pressing the
[2]
or
[8]
button displays each count printed (pressing the
[*]
or
[#]
button is disabled).
3. Press the
[4]
button to end the option (the state in step 1 is restored).
Upper Display
Lower Display
Format
Unit
Function
K-
IMPRESSIONS
******** PRINTS
DEC
Prints
Each displays the number of
each color’s images printed.
Y-
IMPRESSIONS
******** PRINTS
DEC
Prints
M-
IMPRESSIONS
******** PRINTS
DEC
Prints
C-
IMPRESSIONS
******** PRINTS
DEC
Prints
TOTAL SHEET
CNT
******** PRINTS
DEC
Prints
Displays the total number of
images printed.
*1 Tow counts apply to duplex print.
3.4.10
Factory-Shipping mode switching
The Factory-Shipping mode switching is used for switching from the Factory to Shipping
mode.
1. Enter the self-diagnostic mode and, until the following message appears, press
the
[2]
or
[8]
button.
FACTORY MODE SET
2. Press the
[6]
button. The following message appears. Press the
[2]
or
[8]
button
until the option to set (refer to the table shown below) appears
FACTORY MODE
SHIPPING MODE *
3. A setting for the option can be selected by pressing the
[6]
button with the option
on the display.
4. Press the
[6]
button with the setting on the display.
The setting is stored in the EEPROM. The state in step 2 is restored.
5. Repeat steps 2 through 4 when necessary.
6. Press the
[4]
button to end the option (the state in step 1 is restored).
Option
Settings
Function
FACTORY
MODE
FACTORY MODE
Establishes the Factory mode (a fuse-cut
disabling mode).
SHIPPING MODE
Deselects the Factory mode to enable the fuse-
cut function.
FUSE INTACT
Note:
****** is either
INTACT or
BLOWN.
BELT UNIT XXXXXX
Displays the fuse status of the transfer belt unit.
FUSE UNIT XXXXXX Displays the fuse status of the fuser.