Menu functions > 34
HDD Setup
(cont.)
Resize
Partition
PCL nn%/
Common mm%/
PSll%/<Apply>
Specifies the size of partition. Specifies a size by ratio to
the whole HDD in % (1% unit).
nn,mm,ll: 1 - 98 and nn+mm+ll=100
The sizes are displayed in the partition list and can be
changed by selecting the partition size to be changed. If
Apply
is selected, the following confirmation message
appears.
Are You Sure? Yes/No
If
No
is selected, you will return to the previous menu.
If
Yes
is selected, the following confirmation message
appears.
Execute Now? Yes/No
If
No
is selected, you will return to the previous menu.
The request to execute the partition size change request
is put into the memory and the hard disk initialization and
partition size change will be executed at next power cycle.
If
Yes
is selected, shutdown takes place. Hard disk
initialization and partition size change will be executed at
Power Off/On cycle. (If one partition size is modified, the
others are also modified.) If any partition size is modified,
Initialization of HDD needs to be executed as well.
If a previously used HDD is installed, HDD initialization
also takes place. If a HDD, which has been used before, is
installed, the layout of this menu may be different from
that of each partition. (The previously used layout will be
displayed.)
In Non-PS machines, PS is replaced by COMMON, so the
message is displayed as “PCL/COMMON/COMMON”.
Format
Partition
PCL
Common
PS
Formats a specified partition.
When the
Enter
button is pressed, the following
confirmation message appears.
Are You Sure? Yes/No
If
No
is selected, you will return to the previous menu.
If
Yes
is selected, the following confirmation message
appears.
Execute Now? Yes/No
If
No
is selected, you will return to the previous menu.
The request to execute partition formatting is put into the
memory and formatting will be executed at next power
cycle.
If
Yes
is selected, shutdown takes place and the partition
is formatted at power Off/On cycle.
In Non-PS machines, PS is replaced by Common, so the
message is displayed as “PCL/Common/Common”.
System
Setup
Near Life
LED
Enable
/Disable
Controls the settings of the
Attention LED
when near
end of life warning of toner, drum, fuser, or belt occurs.
Attention LED is lit when enabled, not lit if disabled.
(Displays LCD message.)
The temporary recovery by opening and closing of the
cover in Life error is not included.
Reset
Section
Counter
Execute
Resets the section counter of print statistics function to
zero.
If
Execute
is selected, exits from the menu.
ITEM
SETTINGS
EXPLANATION
Содержание ES3032a4