4.
Loosen gas charging valve 4 to counterclockwise
about 1 turn.
5.
Open the main valve for the gas cylinder.
6.
Adjust the gas pressure to the specified pressure
by turning the regulator handle.
Note:
Gas pressure varies
depending on
temperature. Adjust the N
2
gas pressure
according to ambient temperature.
Note:
Refer to page 90 for the specified pressure.
7.
Tighten gas charging valve 4 clockwise to 29 N
m
(21 ft
lb).