44
6
.
If the gauge pressure is within the range limit,
tighten gas charging valve 4 to 29 N
m (21 ft
lb).
Then screw cap 6 (with O-ring) to the uniform
torque.
Cap 6 (with O-ring) Uniform Torque
80 N
m (59 ft
lb)
[100107]
7
.
Open the release valve of the accumulator gas
charging kit, to release residual pressure.
8
.
Remove the accumulator gas charging kit, and then tighten plug 8 (with O-ring) to the uniform torque.
Check that there is no gas leakage.
Plug 8 (with O-ring) Uniform Torque
80 N
m (59 ft
lb)
[100107]