56
Routine and periodic inspection
Part
Check Item
Countermeasure
Frequency
Grease nipple(s)
Grease-up
Every 2 hours
All bolts and nuts
Tightness
Retighten
Everyday
Chisel set pin(s)
Wear or damage
Replace
Everyday
Flange plugs for retainers
Tightness
Retighten
Everyday
Hydraulic oil
Insufficiency, deterioration or
contamination
Replenish or replace
Everyday
Replace
Every 600 hours *
2
Bracket
Wear or damage
Repair or replace
Every 1 month or 100 hours *
1
Chisel
Wear or damage
Repair or replace
Every 1 month or 100 hours *
1
Hydraulic oil filter
Replace
Every 100 hours *
2
Back cap N
2
gas
Gas pressure
Charge N
2
gas
Every 3 months or 300 hours *
1
Shank bushing
Wear or damage
Remove flaws or replace
Every 3 months or 300 hours *
1,
*
3
Front cap bushing
Wear or damage
Remove flaws or replace
Every 3 months or 300 hours *
1,
*
3
All seals
Replace
Every 12 months or 1000 hours *
1
Accumulator bladder
Replace
Every 12 months or 1000 hours *
1
Valve
Flaws on the sliding surface
Repair flaws
Every 12 months or 1000 hours *
1
Cylinder
Flaws on the inner surface,
loosen plug
Repair flaws, retighten
Every 12 months or 1000 hours *
1
Cylinder sleeve
Flaws on the inner surface
Repair flaws
Every 12 months or 1000 hours *
1
Piston
Flaws on the inner surface
Repair flaws
Every 12 months or 1000 hours *
1
*
1
Take steps, whichever comes first.
*
2
As prescribed by the carrier machine manufacturer.
*
3
Refer to the “Wear limit dimension of parts” for visual decision.
●
Shorten the inspection and replacement frequency if the breaker is repeatedly used continuously for many hours.
●
The numbers above are not to assure the lifetime of each part.
Содержание TOP Series
Страница 48: ...48 Exploded view 6 4 7 5 8 9 3 2 10 1 12 11 Hex 22 Hex 22 Hex 5 This part can not disassemble A A A A ...
Страница 50: ...50 Blank page ...
Страница 57: ...57 Blank page ...
Страница 64: ...64 ...