arEa - (group of rooms)
The rooms that are to be set as part of the WLCT2 area will follow the temperature settings of the room controller example, an area could
be the living room, kitchen, and children’s rooms, having a high room temperature requirement during afternoon and early evening, and
a lower temperature during the early part of the day and at night. Each room sensor will have a channel number, designated CH1, CH2
etc. The appropriate channel number of any room sensor is determined by the numbered output on the master control which is actually
switching the valve/actuator for that area.
For example, a system may have the kitchen room sensor operating master output # 4, and the childrens room sensor operating master
output #5. If the WLCT2 room controller is then situated in the living room, and operating output #1, then the WLCT2 need be programmed
to control outputs 1, 4, & 5. (Each room sensor will have been set to operate its appropriate output ch see separate instructions).
To do this, enter the ArEA sub menu., and press Ok ( ) button. CH 1 will be displayed; use the Ok ( ) button and then the UP (
△
) button
to change the setting to ON. Press Ok (
) and CH 2 is displayed. Use the UP (
△
) button until CH4 is displayed, press Ok ( ), and change
to ON. Repeat this for CH 5. All three room sensors will now operate under the control of the WLCT2 room controller.
In total up to 14 Channels can be programmed in this way, and it is possible to have more than a single room controller, each own sub
room sensors operating to its schedule and temperatures.
Set the Channels / Rooms (Ch) to ON if they should follow the settings
of this clock thermostat.
In total 14 channels / rooms can be controlled.