background image

Type ICD3-1999

I N ST R U CT I O N S

English

The electronic comfort controller is a clock
thermostat that can be programmed to function
as a floor temperature controller and room
temperature controller with a limitation function.
The thermostat is intended for mounting in a
55 mm standard wall socket. The operating area
ranges from +0° to +30°C. The thermostat
incorporates a clock enabling the programming
of several setback functions.

Controller setting ICD3

Program choice:

Floor temperature control
Floor temperature control with 2 sensors
Air temperature control
Air temperature control with floor
temperature limit
Regulator control
External control

The controller is designed in accordance
with current product standard EN 60730-2-
9, and fulfill hereby the requirements to
both LVD and EMC directives.

The controller must not be put into operation
until it has been ascertained that the entire
installation complies with current general safety
requirements for electrical installations.

Technical data

Supply voltage . . . . . . . . . . .230V ±10%, 50 Hz
Output relay SPST . . . . . . . . . . . . . .16A, 3600W
Temperature range . . . . . . . . . . . . . . . .+0/+30˚C
Temperature limitation . . . .min./max. +5/+55˚C
Clock function . . . . .1 pre-installed programmes

28 optional setback programmes

Ambient temperature . . . . . . . . . . . . . . .0/+30˚C
On/off differential . . . . . . . . . . . . . . . . . . . .0,4˚C
Housing . . . . . . . . . . . . . . . . . . . . . . . . . . .IP 20
Sensor type . . . . . . . . . . . . . . . . . . . . . . . . .NTC
- heating is switched off in case of sensor failure
Dimensions (HxWxD) (fig. 6) . . . . .86/86/48 mm

The controller is maintenance-free.

Control pollution degree: 2

Pollution degree 2 is representative of normal
household air circulation.

Overvoltage category: III

Classification

The product is a class II device (reinforced
insulation) and the product must be connected
to the following conductors:
1) Phase (L)
2) Neutral (N)

The thermostat is constructed to store the clock
up to 4 hours at an occasional voltage
interruption. It is not suitable for use by regular
voltage interruptions. (Example: Power term
applications). At such conditions a constant
power supply for the thermostat must be
ensured.

WARNING – Important Safety Instructions

Isolate supply before carrying out any
installation or maintenance work on this control
unit and associated components. This control
unit and associated components should only be

installed by a competent person (i, e qualified
electrician). Electrical installation to be in
accordance with latest IEE Wiring Regulations
and appropriate Statutory Regulations.

Mounting of sensor

Floor sensor:

Placed in an approved non

conductive installation pipe in accordance with
EN 61386-1, which is embedded in the floor.
(fig. 3). The pipe is closed in the end and placed
as high as possible in the concrete layer. The
installation pipe must be centered in between
the heating cable.

The enclosed 3 meter sensor cable can be
extended up to 100 m by means of a separate
cable. If the extension cable is lighter than
H05VV-F, it shall equally be installed in an
unbroken installation pipe between the sensor
cable and the extension cable. Two remaining
cores of a multi-core cable which, for example,
supplies current to the heating wires of a floor
heating system, must not be used. The
switching peaks of such current supply lines
may create interfering signals that prevent
optimum controller function. The two-corecable
must be placed in a separate pipe.

Controller installation site

The controller must be mounted on the wall so
that air can circulate freely around it (fig. 4). An
installation site must be selected where the
controller is not exposed to foreign energy
sources, e.g. solar radiation. The controller must
not be exposed to draughts coming from, for
example, windows, doors or cold outer walls.

The controller has a built-in fault interrupter
circuit which interrupts the heating in case of
disconnected or short-circuited sensor.

Mounting of controller

The single gang mounting box must have a
debt of no less than 25 mm.
1. Use a screwdriver in both sides to open the

lock.
The cover must be dismounted (fig. 1).

2.

Connect cables according to the diagram
(fig. 2a-2b).

All electrical connections must be performed by
a fully qualified and Part P certified electrician.

3. Place the screws in front through the holes in

the thermostats and mount them in the wall
socket. The cover is remounted.

Programming

(See user manual)

The controllers are delivered with a pre-installed
setback programme.

If the pre-installed setback programme is not
used, there are different programmes which can
be selected and used on the required days.

The controllers calculate when the heating is to
be switched on to make sure that the comfort
temperature is obtained to the required time.

Fault location

If the sensor is disconnected or short-
circuited, the heating system is switched off.
The sensor can be checked according to the
resistance table fig. 5.

Environment and recycling

Please help us to protect the environment by
disposing of the packaging in accordance with
the national regulations for waste processing.

Recycling of obsolete appliances

Appliances with this label must not
be disposed off with the general
waste. They must be collected
separately and disposed off
according to local regulations.

OJ ELECTRONICS A/S

Stenager 13B · DK-Sønderborg · Denmark
T. +45 73 12 13 14 · F. +45 73 12 13 13
[email protected] · www.ojelectronics.com

Español

El controlador electrónico de confort es un
termostato cronometrado que se puede
programar para funcionar como controlador de
temperatura del piso y como controlador de
temperatura ambiente con una función
limitadora.
El termostato está diseñado para montaje en un
receptáculo de pared estándar de 55 mm. Los
límites de funcionamiento son de 0° a +30 °C.
El termostato incorpora un reloj que permite la
programación de varias funciones de reducción
de temperatura.

Ajuste de controlador ICD3

Opción de programa:

Control de temperatura de piso
Control de temperatura de piso con 2
sensores
Control de temperatura del aire
Control de temperatura del aire con límites
de temperatura de piso
Control regulador
Control externo

El controlador está diseñado de acuerdo
con las normativas de producto vigentes
EN 60730-2-9, y por lo tanto cumple los
requisitos de las directivas LVD y EMC.
No se debe accionar el controlador antes de
verificar que toda la instalación cumpla con los
requisitos vigentes de seguridad general para
instalaciones eléctricas.

Datos técnicos

Tensión de alimentación . . .230 V ±10%, 50 Hz
Relé de salida SPST . . . . . . . . . . .16 A, 3600 W
Rango de temperatura . . . . . . . . . . . .+0/+30 °C
Limitación de temperatura .mín./máx. +5/+55 °C

Función del reloj . . . . . .1 programa preinstalado

. . . . . . . . . . .28 programas opcionales

. . . . . . . .de reducción de temperatura

Temperatura ambiente . . . . . . . . . . . . .0/+30 °C
Diferencial Activado/Desactivado

. . . . . .0,4 °C

Protección . . . . . . . . . . . . . . . . . . . . . . . . . .IP 20
Tipo de sensor

. . . . . . . . . . . . . . . . . . . . . .NTC

- Se apaga la calefacción si falla el sensor . . . . .
Dimensiones (Alt.xAxProf.) (fig. 6) .86/86/48 mm

El controlador no requiere mantenimiento.

Control del grado de contaminación: 2

El grado de contaminación 2 es representativo
de la circulación de aire en la vivienda.

67068 06/11 (MBC)

NW107UW-A

1

© 2011 OJ Electronics A/S

67068-06-11.qxd:57627B  29/06/11  9:03  Side 1

Содержание OJ Microline ICD3-1999

Страница 1: ... be selected where the controller is not exposed to foreign energy sources e g solar radiation The controller must not be exposed to draughts coming from for example windows doors or cold outer walls The controller has a built in fault interrupter circuit which interrupts the heating in case of disconnected or short circuited sensor Mounting of controller The single gang mounting box must have a d...

Страница 2: ...echos generales Estos deben ser recolectados separadamente y eliminarse de acuerdo con las normativas locales OJ ELECTRONICS A S Stenager 13B DK Sønderborg Denmark T 45 73 12 13 14 F 45 73 12 13 13 oj ojelectronics com www ojelectronics com Deutsch Der elektronische Komfortregler ist ein Uhrenthermostat der als Bodentemperatu rregler oder Raumtemperaturregler mit Begrenzungsfunktion programmiert w...

Страница 3: ...δηγίες ασφαλείας Αποµονώστε την παροχή ρεύµατος πριν προχωρήσετε σε εργασίες εγκατάστασης ή συντήρησης σε αυτή τη µονάδα ελέγχου και τα εξαρτήµατά της Αυτή η µονάδα ελέγχου και τα σχετικά εξαρτήµατα πρέπει να εγκαθίσταται µόνο από κατάλληλο προσωπικό πιστοποιηµένο ηλεκτρολόγο Η ηλεκτρική εγκατάσταση πρέπει να γίνει σύµφωνα µε τους τελευταίους κανονισµούς IEE και τους ισχύοντες κρατικούς κανονισµού...

Страница 4: ...dindo o funcionamento óptimo do controlador O cabo de 2 condutores deve ser instalado em conduta separada Local de instalação do controlador A montagem do controlador na parede deve permitir a circulação livre do ar em seu redor fig 4 O local de instalação deve ser seleccionado de modo a não expor o controlador a fontes de energia estranhas como por exemplo a radiação solar O controlador não dever...

Страница 5: ...collectés et rebutés en conformité avec les règlements locaux OJ ELECTRONICS A S Stenager 13B DK Sønderborg Denmark T 45 73 12 13 14 F 45 73 12 13 13 oj ojelectronics com www ojelectronics com Nederlands De elektronische comfortregelaar is een klokgestuurde thermostaat met te programmeren begrenzende functies die te gebruiken is als temperatuurregelaar voor de vloer en voor de ruimte De thermostaa...

Страница 6: ...okres do 4 godzin w przypadku okazjonalnej przerwy w dostawie prądu Nie nadaje się jednak do stosowania w wypadku regularnych zakłóceń napięcia np stosowanie prądu chwilowego W takich warunkach konieczne jest zapewnienie stabilnego zasilania termostatu UWAGA Ważne wskazówki dotyczące bezpieczeństwa Przed przystąpieniem do jakichkolwiek prac instalacyjnych lub konserwacyjnych przy jednostce kontrol...

Страница 7: ...1 6m Fig 4 Fig 6 Fig 1 Fig 2a Master slave function Fig 2b Fig 5 Fig 3 7 2011 OJ Electronics A S 67068 06 11 qxd 57627B 29 06 11 9 03 Side 7 ...

Страница 8: ...13B DK Sønderborg Denmark T 45 73 12 13 14 F 45 73 12 13 13 oj ojelectronics com www ojelectronics com The trademark is registered and belongs to OJ Electronics A S 2011 OJ Electronics A S 67068 06 11 qxd 57627B 29 06 11 9 03 Side 8 ...

Отзывы: