Equation to calculate number of minutes that could be entered in the EN50559
menu - when an average heating effect is desired:
Average wanted heating effect pr. m
2
Floor heating element effect pr. m
2
(
1-
(
)
)
∗
60 min .
Note! If the result of the equation is negative, then nothing should be entered .
1 . Tap the “
Menu
” button on the home screen .
2 . Then tap the “
Engineer Settings
” button .
3 . Scroll down and tap the “
EN50559
” button .
4 . Use the “
Up Arrow
” or “
Down Arrow
” button to set the number of minutes - the
thermostat should not heat per hour .