Commission delegated regulation (EU) No 811/2013 Annex IV
6
8
10
13
17
21
Total rated heat output of heat pump and
supplementary heater
P
rated
+
P
sup
kW
5 + 6 7 + 6 9 + 6 12 + 6 15 + 6 19 + 6
Seasonal space heating energy efficiency
η
s
%
145
150
157
157
156
159
Annual electricity consumption, space
heating
Q
HE
kWh
2821 3629 4689 5969 7940 9631
Sound power level
L
WA
dB(A) 40
44
45
47
ECO:
48
CUBE:
–
ECO:
46
CUBE:
–
Specific precautions that shall be taken when the space
heater is assembled, installed or maintained
1)
1)
1)
1)
1)
1)
Standard rating conditions (brine 0/−3 °C, water 47/55 °C), colder and warmer climate conditions
Total rated heat output of heat pump and
supplementary heater under colder climate
conditions
P
rated
+
P
sup
kW
5 + 6 7 + 6 9 + 6 12 + 6 15 + 6 19 + 6
Total rated heat output of heat pump and
supplementary heater under warmer climate
conditions
P
rated
+
P
sup
kW
5 + 6 7 + 6 9 + 6 12 + 6 15 + 6 19 + 6
Seasonal energy efficiency under colder
climate conditions, space heating
η
s
%
150
156
162
162
161
164
Seasonal energy efficiency under warmer
climate conditions, space heating
η
s
%
146
152
158
159
158
161
Annual electricity consumption under colder
climate conditions, space heating
Q
HE
kWh
3259 4181 5413 6892 9177 11146
Annual electricity consumption under warmer
climate conditions, space heating
Q
HE
kWh
1808 2317 2997 3818 5075 6157
Commission delegated regulation (EU) No 811/2013 Annex IV
6
8
10
13
Product fiche, combination heaters (CUBE only)
Supplier’s name or trademark
Oilon Oilon Oilon Oilon
Supplier’s model identifier
Cube
6 07
Cube
8 07
Cube
10 07
Cube
13 07
Standard rating conditions (Brine 0/−3 °C, water 47/55 °C), average climate conditions
Water heating load profile
L
L
L
L
Water heating energy efficiency class (starting from
September 26, 2016)
A
A
A
A
Annual electricity consumption, DHW heating AEC
kWh
1571 1526 1462 1472
Energy efficiency, DHW heating
η
wh
%
107
110
115
114
The combination heater can be timed to operate outside off-
peak periods
Yes
Yes
Yes
Yes
Specific precautions that shall be taken when the space
heater is assembled, installed or maintained
1)
1)
1)
1)
Annual electricity consumption under colder
climate conditions, DHW heating
AEC
kWh
1571 1526 1462 1472
Annual electricity consumption under warmer
climate conditions, DHW heating
AEC
kWh
1571 1526 1462 1472
Seasonal energy efficiency under colder
climate conditions, space heating
η
s
%
150
156
162
162
Seasonal energy efficiency under warmer
climate conditions, space heating
η
s
%
146
152
158
159
Energy efficiency under colder climate
conditions, DHW heating
η
wh
%
107
110
115
114
Energy efficiency under warmer climate
conditions, DHW heating
η
wh
%
107
110
115
114
M8006 2314EN
57 (59)