Troubleshooting
Trouble
Cause
Corrective measures
T
he machine does
not operate though
the power switch is
turned ON.
Power is not supplied.
Check the connection of the
power supply of the AC power
adapter.
A screw hasn't been removed from
the pickup spot for a certain amount
of time.
Take the screw out from the
pickup site.
Too many screws were loaded into the
scooping hopper.
Adjust the timer setting knob.
Reduce the quantity of screws in
the scooping hopper to a proper
load level.
A foreign object (for example: a
screw) intruded into the main body.
Remove the foreign object.
The AC adapter is faulty.
Consult our service section.
[Model number UI315-15]
Screws do not flow
Screws with a larger diameter than
the specified rail size were loaded or
screws with a different diameter were
mixed in together.
Use screws with the specified
nominal diameter.
Remove the screws with the odd
nominal diameter.
An insufficient quantity of screws is in
the scooping hopper.
Add a proper quantity of screws
into the scooping hopper.
Screws do not flow
Screws in an abnormal position in the
passing plate cannot be swept away
with the brush.
Adjust the brush.
Adjust the passing plate.
If a proper amount of screws is
loaded into the scooping
hopper, the status may be
improved
The axis of the screw thread entered
the passing plate.
Remove the abnormal screw and
check and adjust the passing
plate.
A screw has stopped in an abnormal
position while moving on the rail.
Remove the screw in the
abnormal position. Take care
not to damage the rail groove.
Move the holding plate bracket
assembly upward to remove the
screw. After, adjust the position
of the holding plate.
The rail does not vibrate.
(For example, a screw is caught in the
hopper.)
Remove the screw that is
obstructing the vibration.
Check the vibration adjustment.
Check that the scraper does not
make contact with the hopper
wall. If no screw is obstructing
the clearance, consult our