background image

Service Manual

 

Page 16 of 50 

Aviator 7000 Series: 
 

Step 

Function 

Explanation 

Default 

1

 

Initialize to 
Defaults (only for 
operation 
configuration) 

ON: Initialize softswitch parameters to the defaults 

 

OFF: Scale will not initialize scale softswitch parameters 

Buzzer 

OFF: No sound when a key is pressed 

 

ON: Strong volume when key is pressed 

Backlight 

OFF: No backlight 

ON: Strong backlight 

 


 

Automatic power 
off and Total 
power off time 

0: Disable both sleep & power off function 

 

1: No sleep function, auto power off after 30 Minutes of non-use 

 

2: Sleep function after 5 minutes of non-use; no auto power off 

 

3: Sleep function after 5 minutes of non-use, Auto power off after 30 
minutes of non-use 

 

4: Sleep function after 15 minutes of non-use, no auto power off 

 

5: Sleep function after 15 minutes of non-use, Auto power off after 30 
minutes of non-use 

Auto-clear of 
Tare and Unit 

ON: Enables automatic clearing when weight is removed from platter  X 
OFF: Disables automatic clearing when the weight is removed from 
platter 

 

Prepack / Fix 
Mode Enable 

ON: Enables Prepack/Fix mode 

OFF: Disables Prepack/Fix mode 

 

Auto PLU 

ON: Search PLU automatically 

 

OFF: Search PLU after depressing the PLU key 

Digital Filter 
Selection 

0: Light digital filtering 

 

1: Medium digital filtering 

2: Heavy digital filtering. 

 

Charge 

ON: Enable battery charge 

OFF: Disable battery charge

 

 

10 

Function keys 

0 = Total Function keys are disabled 

 

1 = Total Function keys are enabled 

11 

PLU Enable 

ON: Enables the storage of unit price 

OFF: Disables this feature 

 

12 

By-Count/X Mode 
Enable 

ON: By-count pricing is enabled 

OFF: By-count pricing is disabled 

 

13 

EURO Phase ** 

1= Phase 1 

2= Phase 2 

 

3= Phase 3 

 

4= Phase 4 

 

14 

Two PLU in one 
preset key 

ON: Two PLUs can be preset in one preset key 

OFF: Only one PLU can be pre-set in one preset key 

 

15 

Communication 
Port 

0: RS232 

1: USB 

 

16 

Communication 
Type ** 

0: Protocol 

1: Printer 

 

17 

Ticket Language 
** 

0 = English 

1 = French 

 

2 = Germany 

 

3 = Spanish 

 

4 = Italian 

 

18 

RS232 
Communication 
Speed 

0= 1200bps 

 

1= 2400bps 

 

2= 4800bps 

 

3= 9600bps 

4= 19200bps 

 

Содержание Aviator 7000 Series

Страница 1: ...Aviator 7000 5000 Service Manual GB Service_Manual_Aviator_V1...

Страница 2: ...Service Manual Page 2 of 50 Dimensions Compact version Tower version...

Страница 3: ...OHAUS Aviator scale product OHAUS RESERVES THE RIGHT TO MAKE REFINEMENTS OR CHANGES WITHOUT NOTICE OHAUS Inc 2010 No part of this manual may be reproduced or transmitted in any form or by any means el...

Страница 4: ...ANY INTERNAL ELECTRONIC COMPONENTS OR INTERCONNECTING WIRING BETWEEN ELECTRONIC EQUIPMENT ALWAYS REMOVE POWER AND WAIT AT LEAST THIRTY 30 SECONDS BEFORE ANY CONNECTIONS OR DISCONNECTIONS ARE MADE FAI...

Страница 5: ...2 18 Czech Republic 48 34 51 03 20 Denmark 54 34 57 45 23 France 41 20 51 00 19 Finland 59 48 70 05 25 Germany 47 00 55 00 20 Greece 34 48 41 45 15 Hungary 45 45 48 35 19 Ireland 51 05 55 05 22 Icelan...

Страница 6: ...ient Conditions 13 3 Entering Operator Configuration Setup 13 3 1 Setup Navigation 14 3 2 Entering Operational Setup 15 3 3 Entering Scale Configuration Setup 18 3 4 Time Date Settings Aviator 7000 on...

Страница 7: ...uld be temperature controlled and meet scale specifications for ambient temperature requirements n Must be free of vibrations such as fork lift trucks close by large motors air currents or frafts from...

Страница 8: ...RH non condensation Weighing function Zero Tare 100g change Hold Euro 1 2lb 1 4lb kg lb Communication None Software update Through RS 232 1 4 2 Aviator 7000 Model Aviator A71P3N Aviator A71P6TN Aviat...

Страница 9: ...0e P Plastic cover Version 5 5000 series 7 7000 series Aviator price computing scale 1 6 Approval Documentation n OIML n CE n NTEP n FCC n UL n CB 1 7 Accessories Description CIMF number Lead acid rec...

Страница 10: ...t be adjusted without breaking the sealing Attention Assuming the user is to use the non automatic scales balance in the legally regulated field the user will be responsible for notifying the appropr...

Страница 11: ...Keyboard layouts by region 1 9 1 Aviator 5000 Keyboard Europe s keyboard Europe s preset card Americas other countries keyboard America s Preset Card Other Countries Preset Card 1 9 2 Aviator 7000 Key...

Страница 12: ...able battery Aviator 7000 provides the alternative to use NIMH and D cell batteries When using rechargeable batteries The battery switch located on the bottom side of the device needs to be switched t...

Страница 13: ...ecautions In order to prevent accidents at work the installer is required to take actions directions and measures that comply with the general regulations for the prevention of industrial accidents al...

Страница 14: ...et 4 Precision measurement manufacturing Set 5 Date Time Setup Only for Advanced line Setup Navigation keys Aviator 5000 Aviator 7000 Enter Setup Leave Setup Enter Setup Group Select the Parameters Go...

Страница 15: ...ff 3 Sleep function after 5 minutes of non use Auto power off after 30 minutes of non use 4 Sleep function after 15 minutes of non use no auto power off 5 Sleep function after 15 minutes of non use Au...

Страница 16: ...removed from platter X OFF Disables automatic clearing when the weight is removed from platter 6 Prepack Fix Mode Enable ON Enables Prepack Fix mode X OFF Disables Prepack Fix mode 7 Auto PLU ON Sear...

Страница 17: ...2 Dialog 06 Price computing X 3 L2 Mettler Toledo Price computing 4 Anker Price computing 5 Dialog 02 04 Price computing 6 NCI_Protocol Price computing 21 VAT ON Price is with VAT X OFF Price is with...

Страница 18: ...ross or Net Zero ON Zero cursor will be illuminated when the gross or net OFF Zero cursor will be illuminated when the gross weight 8 Display uuuuu s When ON Show uuuuu s when weight is less than zero...

Страница 19: ...ow negative weight when under zero 9 Tare Enable ON Enables tare function OFF Disables tare function 10 Chain Tare Enable ON Enables chain multiple tares OFF Only one tare per transaction is allowed 1...

Страница 20: ...or period Decimal Point Position Select for Price Displays Currency Enable Zero Cursor China 12 3 CN 1 2 1 Germany 20 0 DE 1 German 2 0 France 19 0 FR 1 French 2 0 USA 12 2 US 1 English 2 1 Austria 1...

Страница 21: ...1 Austria 18 0 0 0 1 1 1 1 0 Spain Portugal 15 0 0 0 1 1 1 1 0 Belgium Netherlands 21 0 0 0 1 1 1 1 0 Italy 17 0 0 0 1 1 1 1 0 Swiss 18 0 0 0 1 1 1 1 0 Ukraine 21 3 0 0 1 1 1 1 0 Russia 23 3 0 0 1 1 1...

Страница 22: ...1 1 1 1 Austria 18 0 1 0 1 0 1 0 0 Spain Portugal 15 0 1 0 1 0 1 0 0 Belgium Netherlands 21 0 1 0 1 0 1 0 0 Italy 17 0 1 0 1 0 1 0 0 Swiss 18 0 1 1 1 0 1 0 0 Ukraine 21 3 1 0 1 0 1 0 0 Russia 23 3 1...

Страница 23: ...f printers not officially recommended by OHAUS for the concerned product line Printers connected to the system not officially recommended by OHAUS might not be covered by the scale approval Get in con...

Страница 24: ...the seal 1 Break the paper seal and unscrew the plastic cover fixation 2 Take off the plastic cover 3 Press the calibration switch with a thin rod Calibration steps Procedure Description Key operation...

Страница 25: ...isplay on 2nd line Display On 3rd line Display on the bottom line Lit cursor Step16 Put the weight on the platter valid weight is about 2 3 capacity Add Step17 Count down from 5 to 0 on off Capture 0...

Страница 26: ...e problem n Make a visual inspection for faulty connectors wiring and loose hardware 4 2 Troubleshooting This section of the manual contains troubleshooting information It includes information to isol...

Страница 27: ...OS n Communication type STEP 16 should be set to Protocol n Verify whether the same communication protocol is selected on scale POS STEP 20 allows the selection of the protocol n Verify if POS printer...

Страница 28: ...charges and wear a static proof wrist belt when touching the PCB 5 1 Service Preparation Use the below procedures to replace the main board display load cell and keyboard Important Notice Assuming th...

Страница 29: ...bration authorities of the repaired scales balance so that the latter can take the appropriate measures calibration recalibration 5 3 Replacing the Main Board Procedure for replacing the board 1 Lift...

Страница 30: ...system is mandatory Attention Assuming the user is to use the non automatic scales balance in the legally regulated field the User will be responsible for notifying the appropriate calibration authori...

Страница 31: ...ap to avoid damage to the load cell Reference the below form Product name Tools Capacity of LC 4 corner gap Mid corner gap Draw corner gap Aviator Q25 1 AMI 5kg 0 60 0 05mm 0 35 0 05mm 0 35mm Q25 2 AM...

Страница 32: ...ighing processes of the same load and of the linearity behavior of the EUT References Product description Weighing Max error 0e m 500e 0 5e 500e m 2000e 1 0e 2000e m max 1 5e Conditions standard condi...

Страница 33: ...ustomer side display 1 Open the top cover please refer to the Opening the Housing chapter service preparations section 2 Disconnect all cables 3 Remove the old display directly 4 Install new display f...

Страница 34: ...emove the old keyboard 4 Install new keyboard following the same instructions in the reverse order Replacing Aviator 7000 keyboard PCB layer 1 Open top cover please refer to opening housing chapter se...

Страница 35: ...erkel 2 Dialog 06 3 L2 Mettler Toledo 4 Anker 5 Dialog 02 04 6 NCI 6 1 1 CAS 6 1 1 1 Data Format 9600 Baud select 2400 4800 or 9600 7 data bits select 7 or 8 Even parity select Even None or Odd parity...

Страница 36: ...and including decimal U6U5U4U3U2 U1U0 Spaces are used for leading non significant digits i e a price of 15 00 would be transmitted as 15 00 with four leading spaces BCC Block Check Character calculate...

Страница 37: ...Request STX 02h Start of text ID Information byte broken down into the following bits Bit Capacity 2 1 0 0 0 1 15kg x 0 005kg 0 1 0 30lb x 0 01lb 0 1 1 6kg x 0 002kg Bit 3 Logic 1 Bit 4 Logic 1 means...

Страница 38: ...lled value KW created by the CRC16 method in use with a polynomial P which is known only by the manufacturers of the scale and the POS system CS and KW both have a length of 16 bit REMARK KW REPRESENT...

Страница 39: ...Tare value 4 digits Text 13 chars Record 08 Status request after receiving NAK EOT STX 08 ETX _ Record No Record 10 Transmitting of checksums EOT STX 10 ESC CS1 KW1 CS2 KW2 CSn KWn ETX _ __________ _...

Страница 40: ...esentation of random number Z like checksums hexadecimal ASCII char 6 1 3 4 Description of the Dialog A dialogue will always be initiated by the POS system Description of weighing operation The POS sy...

Страница 41: ...on off The POS system can display the version number of the software in the scale If the scale receives record 20 EOT STX 20 ESC 1 ETX it will display the version number until it receives EOT STX 20...

Страница 42: ...wing chars in display in display in display To display abbreviation letters ex F use small letters Ex f F in display GXXXXXAAAAAAAAAAAAAA CR LF price TLU or GXXXXXTxxxxAAAAAAAAAAAAAA CR LF price tare...

Страница 43: ...it Parity Parity odd Stop bit 1 Bit EOT STX SATZ 03 ETX STX SATZ 04 ETX ETX STX SATZ 05 ETX STX SATZ 10 ETX STX SATZ 20 ETX ENQ STX ETX S A T Z 1 1 3 2 H Z ACK NAK EOT STX SATZ 02 STX NAK ETX ETX S A...

Страница 44: ...Service Manual Page 44 of 50 6 1 5 Anker Note Scale replies to L5 request with SOH if in motion under zero over capacity can not capture zero or if there is no weight available...

Страница 45: ...s if there is invalid data in the setting 6 1 6 3 Command Descriptions POS System Communications to a Scale Setting number 01 Basic Price EOT STX 30h 31h ESC D5 D4 D3 D2 D1 D0 ESC ETX _____ __________...

Страница 46: ...ore symbols that are permitted 10 invalid setting no 11 invalid basic price 12 invalid tare value received 13 invalid text received 20 scale is still in motion no standstill 21 scale wasn t in motion...

Страница 47: ...SP xx xOZ CR LF Shh CR ETX Scale status only if wt 0 initial zero error in motion or out of capacity LF Shh CR ETX Name Request status Command S CR Response Returns scale status LF Shh CR ETX Name Ze...

Страница 48: ...plus five one for the decimal point two for the LB and two for the OZ Units of measure will appear in their ANSI standard abbreviated form LB for pounds KG for kilograms etc in uppercase characters Ze...

Страница 49: ...1 Scale at zero 0 Not at zero 1 Over capacity 0 Not over capacity 1 Zero Detected 0 No Zero Seen 2 1 RAM error 0 RAM okay 1 ROM error 0 Calibration okay 1 Net weight 0 Gross weight 1 Metric 0 English...

Страница 50: ...Set OP Setting S15 1 S16 0 7 2 2 Choose protocol Set OP Setting S20 to select correct protocol 7 2 3 Install driver and Connect Install the virtual COM driver Please go back to your scale manufacturer...