Assembly
Setup
Before assembling the test cell, make sure the fixtures on the side are
adequately greased. This will prevent cement slurry from hardening inside the
fixtures and damaging the parts.
1.
Unscrew the transducer assembly and completely fill the space inside
with high-temperature grease. Replace the transducer, then open the
relief valve and fill the remaining space. Close the relief valve.
2.
Remove the thermocouple and inject the grease directly into the fixture.
3. Replace the thermocouple.
To verify that enough grease has been used, look into the cell and
observe the two holes on the side. You should be able to see grease
overflowing the two fixtures into the test cell. Wipe any excess grease
from the inside of the cell.
Grease
Transducer
Assembly
Thermocouple
Transducer
Syringe
Thermocouple
Fixture