26
PV
PV input voltage
PV input current
PV input power
PV input capacity
Utility
Utility input voltage
Utility charging input current
Utility charging input power
Utility input capacity
Battery Type
AGM
GEL
FLD
LFP8/LFP15/LFP16
LNCM7/LNCM14
AGM/GEL/FLD/LFP/LNCM+USER
3.4
Operating mode
3.4.1
Abbreviation
Abbreviation
Illustration
P
PV
PV power
P
LOAD
Load power
V
BAT
Battery voltage
LVR
Low voltage reconnect voltage
LVD
Low voltage disconnect voltage
AOF
Auxiliary module OFF voltage
AON
Auxiliary module ON voltage
MCC
Max charging current
3.4.2
Battery mode
INPUT
Solar
Only solar energy can charge the battery, no matter utility is available
or not.
Solar Priority
When PV power is sufficient, PV charges the battery. When the
battery voltage is lower than AON, the utility charges the battery as a
supplement; when the battery voltage is higher than AOF, the utility
stops charging the battery.
Note: AOF and AON setting refers to Item 17/18 on the Advanced
interface for engineers.
Utility & Solar
PV and utility charge the battery at the same time. When PV power is
sufficient, the PV power is the primary source.
Note: After selecting this working mode, the output mode is not