41
37
Utility over
voltage
disconnecti
on voltage
264.0V
(Default for the 220V system
)
User define:
220VAC~290VAC
Step size: long press for 10V
,
short press for 1V
38
Utility low
voltage
disconnecti
on voltage
176.0V
(Default for the 220V system
)
User define:
90VAC~190VAC
Step size: long press for 10V
,
short press for 1V
39
Battery
discharge
current
limit
Refer to
3.7 for
details.
IC-24/3000/100/80
: 300A (
Default
)
User define: 10~300A
IC-48/5000/80/60
: 250A
(Default)
User define:10~250A
Step size: Long press for 10A
,
short press for 1A
40
lithium
battery
protocol
type
1
(Default)
User Define:1~10
NOTE: Refer to the (3) Lithium battery BMS Interface
of chap 1
41
BMS
enable
0
(Default)
1
Normal BMS comm.
:
The BMS controllers the
UP-Hi charge and discharge.
Error BMS comm.:
The UP-Hi automatically enters
the no-battery mode and display BME.
42
Software
version
U-1.0
(Default)
It cannot be modified.
NOTE: Detail version refers to the actual display.
3.6
Battery voltage customized logic.
For the above items7-16 and 33-36, please follow the below rules strictly.
1) In the 24V input voltage system, the following rules must be followed when modifying the parameter
values in the user battery type for a Lead-acid battery.
A.
Over Voltage Disconnect Voltage
≥
Over Voltage Reconnect 0.5V
B.
Over Voltage Disconnect Voltage > Charging Limit Voltage
≥
Equalize Charging Voltage
≥
Boost Charging
Voltage
≥
Float Charging Voltage > Boost Reconnect Charging Voltage
C.
Low Voltage Reconnect Voltage
≥
Low Voltage Disconnect 0.5V
D. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage
≥
Discharging Limit Voltage(21.2V)
E.
Under Voltage Warning Reconnect Voltage-0.5V
≥
Under Voltage Warning Voltage
≥
Discharging Limit
Voltage(21.2V)