OETIKER ELK 02 V2.X
13
Technical data
Issue 05.2021
08903352
13-124
Data output at X3 on each completed step in step-by-step
Message text
Meaning
_002 Ready for closure
The ELK 02 is at the closure level and is waiting for a start from the user
OS-OK
The opening gap has been reached. The ELK 02 is waiting for the hold
function to be started
F:___0 N
Force value for opening gap
S:_9,99 mm
Opening gap
HS-OK
Holding gap and holding force have been reached. The ELK 02 is waiting for
the closure function to be started
F: 344 N
Holding force
S: 10.87 mm
Holding gap
V24 standard data output (only if this function is enabled)
Clamp type
Pincer type Text
H V 12.0
4.0
4.0
10.87 300 150
150
344 0 OK
SS/SK-OK
Closing gap and closing force were reached. The ELK 02 is waiting for the
verification function to be started
F: 5035N
Closing force
S: _3.76 mm
Closing gap
V24 standard data output (only if this function is enabled)
Clamp type
Pincer type Text
S V 9.0
9.0
9.0
3.76
5000 250 250 5035 0 OK
VW-OK
Verification gap and verification force have been reached. ELK 02 is waiting
for the opening function to be started
F:__84N
Verification force
S:_2.34 mm
Verification gap
V24 standard data output (only if this function is enabled)
Clamp type
Pincer type Text
V V 2.0
1.5
1.5
2.34
100 60
60
84
0 OK
OF-OK
The pincer is open again, the closure has been completed.
F:___0N
Force value for opening gap
S:10.99mm
Opening gap
_002 Ready for closure
The ELK 02 is at the closure level and is waiting for a start from the user
Table 37
Data output at X3 at each completed step in step-by-step
Message text
Meaning
Error 8
Error output here: Error 8 “APN not assigned”.
Table 38
Data output at X3 on error
Содержание ELK 02 Series
Страница 144: ...Blank page ...