9
Electric Connection
Connect the unit to a 400 V power source which is protected by 3 x 16 A
(slow). Extension cables to have a diameter according to VDE regulations.
Extension cables on reels to be reeled off completely, in order to avoid
overheating of the cable reel. Plugs, couplings to be water-proof. A faulty
current protection switch is recommended. VDE regulations apply.
High Pressure Connection
High pressure hose to be connected to high pressure outlet (11) of the
machine by means of the hand nut without using tools.
Detergent Tank Filling
Fill detergent tank (17) with non-hazardous detergent. When using powders,
these have to be mixed in a separate tank before being filled into the detergent
tank of the machine. Tank to be properly closed after filling.
Fuel Tank Filling
Fill fuel tank (19) with clean fuel oil according to DIN 51603, part 1 or Diesel.
Absolute cleanliness to be guaranteed during transportation and filling. In case
of oil shortage (indicator lamp c) fill tank. Tank to be properly closed after
filling.
Anti-Scalant Tank Filling
Fill anti-scalant tank (28) with OERTZEN anti-scalant liquid ORM 30. Never run
the machine with empty anti-scalant tank. Tank to be properly closed after
filling.