After Completion of Work
Turn thermostat (23 a) into pos. 0. Run machine in cold water mode for a
couple of minutes.
Close spray pistol.
Switch off machine by means of the ON/OFF/burner switch (2 a).
De-pressurise spray pistol by shortly opening and closing.
Lock spray pistol.
Disconnect machine from water and power sources.
Reel off high pressure hose and thoroughly clean it. In case of damage
replace it for safety reasons.
Using other materials than original OERTZEN equipment (hand nut respec-
tively hose marked with “OERTZEN”) or using materials which have not
expressively been approved by OERTZEN in writing ceases warranty and
product liability.
Reel up high pressure hose properly, without loops.
Store equipment in a dry, frost-protected area.
In case of extended shut-down periods drain pump completely.
Particularly Note
In case of malfunctions switch off machine immediately, eliminate cause
according to chapter "Trouble Shooting", call qualified service.
If frost is likely, frost protection of the machine is a must, as otherwise severe
damage could occur.
After work spray pistol to be locked to avoid
unauthorised/accidental operation.