English 14 English
The Burnback Time
is the amount of time that the weld
output continues after the wire stops feeding. It prevents
the wire from sticking in the puddle and prepares the end
of the wire for the next arc start.
Run-in WFS
sets the wire feed speed from the time the
trigger is pulled until an arc is established.
Spot Timer
adjusts the time welding will continue even if
the trigger is still pulled. This option has no effect in 4-Step
Trigger Mode.
WARNING
Spot Timer has no effect in 4-Step Trigger Mode.
Preflow Time
adjusts the time that shielding gas flows
after the trigger is pulled and prior to feeding.
Postflow Time
adjusts the time that shielding gas flows
after the welding output turns off.
Welding GMAW in Synergic Mode
(CITOMIG 210MP only)
In synergic mode, the welding load voltage is not set by
user. The correct welding load voltage will set by the
machine’s software. This value was recalled on the basis
of data (input data) had been loaded:
CITOMIG 210MP
Basic menu
Advanced menu
Wire
type
(material)
Wire
diameter
Gas
Wire
type
(material)
Wire
diameter
Gas
The welding load voltage can be changed depend on the
value of parameters are set by operators:
CITOMIG 210MP
Basic menu
Advanced menu
WFS
Welding
current
Material
thickness
WFS
Welding
current
Material
thickness
If it is needed, the welding load voltage can be adjusted ±
2V by the right knob [11].
Additionally, user can manually set:
CITOMIG 210MP
Basic menu
Advanced menu
No possibilities
Burnback
Run-in
WFS
Spot
Timer
Preflow Time / Pastflow
Time
2-STEP/4-STEP
Inductance
The 2-Step - 4-Step
changes the function of the gun’s
trigger.
2 Step trigger operation turns welding on and off in
direct response to the trigger. Welding process is
performed when the gun’s trigger is pulled.
4-Step mode allows to continue welding, when the
gun’s trigger is released. To stop welding, the gun’s
trigger is pulled again. 4-step mode facilitates to
making long welds.
WARNING
4-Step does not work during Spot Welding.
The Burnback Time
is the amount of time that the weld
output continues after the wire stops feeding. It prevents
the wire from sticking in the puddle and prepares the end
of the wire for the next arc start.
Run-in WFS
sets the wire feed speed from the time the
trigger is pulled until an arc is established.
Spot Timer
adjusts the time welding will continue even if
the trigger is still pulled. This option has no effect in 4-Step
Trigger Mode. Adjusting range:
WARNING
Spot Timer has no effect in 4-Step Trigger Mode.
Preflow Time
adjusts the time that shielding gas flows
after the trigger is pulled and prior to feeding.
Postflow Time
adjusts the time that shielding gas flows
after the welding output turns off.
Welding SMAW (MMA) Process
CITOMIG 185MP
and
CITOMIG 210MP
does not include
the electrode holder with lead necessary for SMAW
welding, but the one can be purchased separately.
Procedure of begin welding of SMAW process:
First turn the machine off.
Determine the electrode polarity for the electrode to be
used. Consult the electrode data for this information.
Depending on the polarity of using electrode, connect
the work lead [19] and the electrode holder with lead
to output socket [8] or [9] and lock them. See the
Table 3.
Table 3.
Output socket
POLARITY
DC (+)
The electrode holder
with lead to SMAW
[8]
Work lead
[9]
DC (-)
The electrode holder
with lead to SMAW
[9]
Work lead
[8]