background image

English 1 English 

Technical Specifications 

 

NAME 

INDEX 

CITOMIG 185MP 

W000403579 

CITOMIG 210MP 

W000403578 

INPUT 

 

185MP 

210MP 

Input Voltage U

1

 

230 Vac ± 10%, 1-phase 

115 Vac ± 10%, 1-phase 

230 Vac ± 10%, 1-phase 

Frequency 50/60 

Hz 

Input Amperes I

1max

 27A 

23A  27A 

Input Power at Rated Cycle (40°C)  6,2kVA @ 25% Duty Cycle 

2,6kVA @ 40% Duty 

Cycle 

6,2kVA @ 25% Duty 

Cycle 

cos 

φ

 0,99 

EMC Group / Class 

II / A 

RATED OUTPUT 

185MP

 

 

Open Circuit 

Voltage 

Duty Cycle 40°C 

(based on a 10 min. period) 

Output Current 

Output Voltage 

GMAW 

51 Vdc 

100 110A 

19,5 

Vdc 

60 160A 

22 

Vdc 

25 200A 

24 

Vdc 

FCAW-SS 

100 110A 

19,5 

Vdc 

60 160A 

22 

Vdc 

25 200A 

24 

Vdc 

SMAW 

100 100A 

24 

Vdc 

60 140A 

25,6 

Vdc 

30 160A 

26,4 

Vdc 

210MP 

230Vac 

GMAW 

51 Vdc 

100 110A 

19,5 

Vdc 

60 160A 

22 

Vdc 

25 200A 

24 

Vdc 

FCAW-SS 

100 110A 

19,5 

Vdc 

60 160A 

22 

Vdc 

25 200A 

24 

Vdc 

SMAW 

100 100A 

24 

Vdc 

60 140A 

25,6 

Vdc 

30 160A 

26,4 

Vdc 

GTAW 

100 100A 

14 

Vdc 

60 140A 

15,6 

Vdc 

40 160A 

16,4 

Vdc 

115Vac 

GMAW 

51 Vdc 

100 75A 

17,7 

Vdc 

60 87A 

18,3 

Vdc 

40 100A 

19 

Vdc 

FCAW-SS 

100 75A 

17,7 

Vdc 

60 87A 

18,3 

Vdc 

40 100A 

19 

Vdc 

SMAW 

100 60A 

22,4 

Vdc 

60 70A 

22,8 

Vdc 

40 80A 

23,2 

Vdc 

GTAW 

100 90A 

13,6 

Vdc 

60 110A 

14,4 

Vdc 

40 125A 

15 

Vdc 

Содержание CITOMIG 185MP

Страница 1: ...IM3080 11 2022 REV05 CITOMIG 185MP 210MP OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 260 Bielawa Poland...

Страница 2: ...he table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial Number Date Where Purchased ENGLISH INDEX Technic...

Страница 3: ...rrent Output Voltage GMAW 51 Vdc 100 110A 19 5 Vdc 60 160A 22 Vdc 25 200A 24 Vdc FCAW SS 100 110A 19 5 Vdc 60 160A 22 Vdc 25 200A 24 Vdc SMAW 100 100A 24 Vdc 60 140A 25 6 Vdc 30 160A 26 4 Vdc 210MP 23...

Страница 4: ...25A 3 Conductor 2 5mm2 210MP DIMENSION Weight Height Width Length 185MP 17 3 kg 396 mm 246 mm 527 mm 210MP WIRE DIAMETER WIRE FEED SPEED RANGE WFS RANGE Solid wires Aluminum wires Cored wires 185MP 1...

Страница 5: ...dition Presence MIG mode X TIG mode STICK mode After 30 minutes of non working Fan off The value of efficiency and consumption in idle state have been measured by method and conditions defined in the...

Страница 6: ...process gas usage depends on cross sectional area of the nozzle For commonly used torches Helium 14 24 l min Argon 7 16 l min Notice Excessive flow rates causes turbulence in the gas stream which may...

Страница 7: ...cesses Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating in or near the work area The opera...

Страница 8: ...electrical regulations ELECTRICALLY POWERED EQUIPMENT Regularly inspect the input electrode and work clamp cables If any insulation damage exists replace the cable immediately Do not place the electr...

Страница 9: ...work area CYLINDER MAY EXPLODE IF DAMAGED Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressur...

Страница 10: ...e Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient temperature greater than 40 C Duty cycle and Overheating The duty cycle of a welding machine...

Страница 11: ...ode and the workpiece 5 WFS Hot Start Control Depending on welding process this knob controls GMAW process Wire feed speed WFS Value in percentage of nominal value wire feed speed SMAW process HOT STA...

Страница 12: ...r GMAW FCAW SS 22 Spooled Wire for GMAW FCAW SS The machine does not include a spooled wire 23 Wire Spool Support Maximum 5kg spools Accepts plastic steel and fiber spools onto 51mm spindle 24 Shield...

Страница 13: ...English 11 English Table 1 Positive polarity factory setting Table 2 Negative polarity...

Страница 14: ...again Adjusting of Force of Pressure Roll Force The pressure arm controls the amount of force the drive rolls exert on the wire Pressure force is adjusted by turning the adjustment nut clockwise to i...

Страница 15: ...to be used Consult the wire data for this information Connect output the gas cooled gun to GMAW FCAW SS process to Euro Socket 7 Depending on the using wire connect the work lead 19 to output socket...

Страница 16: ...ges the function of the gun s trigger 2 Step trigger operation turns welding on and off in direct response to the trigger Welding process is performed when the gun s trigger is pulled 4 Step mode allo...

Страница 17: ...r Procedure of begin welding of GTAW process First turn the machine off Connect GTAW torch to 9 output socket Connect the work lead to 8 output socket Connect the work lead to the welding piece with t...

Страница 18: ...on Inductance Select Gas Switch On Output Voltage TIG MMA only Spot Welding Setting Select Wire Type material Switch Off Output Voltage TIG MMA only Spot Timer Select Wire Size diameter Unlock panel S...

Страница 19: ...be disconnected from the machine before each maintenance and service After each repair perform proper tests to ensure safety Customer Assistance Policy The business of The Lincoln Electric Company is...

Страница 20: ...n this printing First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine which contains a picture descriptive part number cross reference REACh...

Страница 21: ...de holder to SMAW process 3m W000260684 WELDLINE lead s KIT to SMAW process The electrode holder with lead to SMAW process 3m Work lead 3m KIT 200A 25 3M Lead s KIT to SMAW process The electrode holde...

Отзывы: