Safety information 
on contamination of compressors, vacuum pumps 
and components. 

 
 
 

Scope 

 

Every employer (user) is held responsible for the health and safety of his employees. This also 
applies to service personnel performing maintenance work either at the premises of the user or the 
service company in charge. 

 

By means of the declaration attached the contractor is to be informed about any possible 
contamination of the compressor, vacuum pump or component sent in for servicing. Based on this 
information the contractor will be able to take the necessary safety precautions. 

 

 
 

Preparation before dispatch 

 
Before shipping any parts, the user must complete the following declaration and add it to the 
dispatch papers. All dispatch instructions laid down in the manual must be followed e.g.: 

 

 

Drain all service fluids

 

 

Remove filter elements

 

 

Seal all openings airtight

 

 

Pack / handle appropriately

 

 

Attach the declaration of contamination outside of the packaging

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание DISPLAY ONE

Страница 1: ...Torr SP Pa mbar 8 8 8 8 8 8 DISPLAY ONE DISPLAY ONE Single Channel Vacuum Display Catalog Numbers 230001 235001 Instruction Manual GA 09 034 2 02...

Страница 2: ......

Страница 3: ...General 6 2 2 Signs and Symbols 6 2 3 Basic Safety Regulations 6 3 General Description 7 3 1 General Functional Characteristics 7 3 2 Applicable Transmitters 7 4 Technical Data 8 4 1 General Data 8 4...

Страница 4: ...n 15 6 4 2 Description 15 6 5 Parameter Mode 16 6 5 1 Selection 16 6 5 2 Description 16 6 5 3 Mass unit 16 6 5 4 Display Format 16 7 Maintenance and Servicing 17 7 1 Maintenance 17 7 1 1 General Maint...

Страница 5: ...tion for Analogue Output and Relay Output 13 Figure 6 Front Panel 14 0 2 List of Tables Table 1 Catalog Numbers 4 Table 2 Applicable Transmitters 7 Table 3 Scope of Delivery 11 Table 4 Display Structu...

Страница 6: ...gure 1 Nameplate example 1 2 Conforming Utilisation The DISPLAY ONE serves as a simple power supply and display unit for the transmitters from the series THERMOVAC and PENNINGVAC 1 3 Responsibility an...

Страница 7: ...case of damage Retain the packaging material because the reconsignment in the original packaging of the manufacturer is prerequisite for warranty claims Check the consignment for completeness Check th...

Страница 8: ...revention of injury by electrical impact REFERENCE General lead on further information and articles respectively 2 3 Basic Safety Regulations During all work such as installation maintenance and repai...

Страница 9: ...ransmitters from the series THERMOVAC and PENNINGVAC 3 2 Applicable Transmitters The following transmitters can be operated via DISPLAY ONE Transmitter Type Display THERMOVAC TTR90 TTR90S TTR91 TTR91S...

Страница 10: ...Dimensions Width 106 0 mm 1 4 19 Height 84 5 mm 2 HE Depth 108 0 mm Weight 0 5 kg Build in depth ca 150 mm including connected plug Application Rack installation Panel mounting Benchtop instrument Fi...

Страница 11: ...ational national standards as well as specifications EN 61010 1 Electrical measuring and control equipment EN 61000 6 2 EMC compatibility EN 61000 6 3 EMC interference 4 2 Mains Connection Voltage 100...

Страница 12: ...bar Pa Torr 4 3 3 Switching Function Type of contact Changeover contact potential free Load resistive Switching current max 1 A Switching voltage max 30 V AC 60 V DC Service life Mechanical 107 actuat...

Страница 13: ...ower disconnection is at any time possible 5 2 1 Rack Installation The DISPLAY ONE is designed for being installed into a rack according 19 2 HU Affix the sub rack within the rack Insert the DISPLAY O...

Страница 14: ...s switch and device fuses B Connection for transmitter Figure 4 page 13 C Connection for relay output and analogue output Figure 5 page 13 D Configuration switch 5 3 2 Mains Connection The mains conne...

Страница 15: ...to the connector Input on the rear of the DISPLAY ONE 5 3 4 Analogue Output and Relay Output The connection Figure 3 C page 12 and Figure 5 page 13 contains the analogue output of the transmitter and...

Страница 16: ...P Switching function status When the icon lights up the pressure is below the lower threshold If the icon does not light up the pressure is above the upper threshold Table 4 Display Structure and Desc...

Страница 17: ...trument different parameters of the DISPLAY ONE Chapter 6 5 Parameter Mode page 16 6 4 Measurement Mode 6 4 1 Selection After switching on the DISPLAY ONE it will automatically run the measuring mode...

Страница 18: ...ays remain in the position OFF 6 5 2 Description Over the configuration switch with DIP switches 1 and 2 the mass unit is stopped as well as selected with DIP switch 3 between two or three figure meas...

Страница 19: ...channel Err Hi Significantly above the measurement range Replace the transmitter Err Lo Significantly below the measurement range Replace the transmitter Table 8 Error Messages 7 2 2 Help in Case of M...

Страница 20: ...lowing ambient conditions need to be maintained Ambient temperature 20 60 C Humidity of the air As low as possible Preferably in a sealed plastic bag with desiccant 8 3 Waste Disposal Regarding waste...

Страница 21: ......

Страница 22: ...is to be informed about any possible contamination of the compressor vacuum pump or component sent in for servicing Based on this information the contractor will be able to take the necessary safety...

Страница 23: ...pplication Process B Condition of the equipment No1 Yes No Contamination No1 Yes 1 1 Has the equipment been used toxic 2 Drained Product service fluid corrosive 3 All openings sealed airtight flammabl...

Страница 24: ...l s Valence Cedex Phone 33 4 75 82 33 00 Fax 33 4 75 82 92 69 info vacuum vc oerlikon com Great Britain Oerlikon Leybold Vacuum UK Ltd Unit 2 Silverglade Business Park Leatherhead Road UK Chessington...