Connection of condensation
draining kit
3.4
54
Swimming pool heat pump
While operating, the heat pump is subject to condensation. That will result in a more or
less large run-off of water, depending on the degree of humidity. To channel this flow, we
recommend the installation of a condensation draining kit.
How do you install the condensation draining kit?
Install the heat pump by means of solid, water-resistant pads raising it at least 10 cm.
Then connect the drainage pipe to the drain opening located under the pump.
Installation on vibration-
absorbing pads
3.5
In order to minimise the noise pollution associated with heat pump vibrations, it can be
positioned on vibration-absorbing pads.
For this, you simply have to position a pad between each of the unit’s feet and its support,
and then fix the heat pump to the support with suitable screws.
Hydraulic connection
3.6
IMPORTANT:
Installation must be carried out by a qualified technician. This section is provided for
information purposes only and has to be checked and adapted if necessary according
to the actual installation conditions.
By-pass assembly
The heat pump must be connected to the pool by means of a by-pass assembly.
The assembly consists of 3 valves that regulate the flow circulating in the heat pump.
During maintenance operations, the by-pass allows for the heat pump to be isolated from
the system without interrupting the operation of the pool.
Open valve
Half-open valve
FROM THE POOL
TOWARDS THE POOL
Outlet
Inlet
GB