Odorox IDU Скачать руководство пользователя страница 5

Odorox

®

 IDU

TM

3

SAFETY INFORMATION

Mercury Spill Kit Suppliers

Crackle Scientific

800-334-7725

Lab Safety Supply

800-356-0783

Cole-Parmer

800-323-4340

For schools only:

Fisher Scientific

800-452-1261

For schools and businesses only:

Fisher Scientific

800-766-7000

Mallinckrodt/Baker

800-582-2537

Sigma Aldrich

800-325-3010

VWR Scientific

800-932-5000

Use the eyedropper to collect mercury beads
and place them in the plastic bag.

 Hold the

eyedropper at an angle to draw the mercury into
the tip. Keep the eyedropper at an angle to stop
the mercury from rolling back out until you can put
the mercury into the plastic bag. Wrap tape (sticky
side out) around your gloved fingers and carefully

use it to pick up any remaining glass or beads.

Check again with the flashlight to be sure that no

beads of mercury remain.

• At this point, mercury beads may still be trapped

in cracks or crevices on irregular surfaces. 

Sprinkle

sulfur powder over the contaminated area

 and

rub it gently all over the surface and into the cracks
with a paper towel. Sulfur powder binds with
mercury. Use a paper towel dampened with water
followed by wiping with another damp paper towel
to clean up the sulfur and mercury. Place the used
paper towels in a zipper-type plastic bag.

Put all the items that were used to pick up the
mercury, including index cards or cardboard,

eyedropper, contaminated tape, paper towels,
and zipper-type bags into the trash bag.

 Carefully

remove rubber gloves by grabbing them at the
wrist and pulling them inside out as they come off.
Place the used gloves in the trash bag.

Carefully seal the trash bag that contains the

mercury-contaminated waste

 and put it in a

secure place, preferable outdoors and out of reach
of children and pets until it can be disposed of
safely.

• If possible, 

open a window and use a fan to

ventilate the area to the outdoors for 24-48

hours

 before resuming normal use. If possible, heat

the area (for example, with a space heater) while
still ventilating to the outdoors. Avoid blowing
the exhaust back indoors or into other nearby
residences.

Clothes or shoes that did not come in direct
contact with liquid mercury should be removed

and put into the trash bag

 that was left outside

the contaminated area at the beginning of the
cleanup. Close the trash bag and take it outdoors.

Carefully remove the shoes and or clothing

from the trash bag and air them out thoroughly
outdoors for 24 to 48 hours. After the outdoor

airing, items that are washable can then be 

laundered.

Dispose of contaminated items properly!

Mercury-contaminated items should not be placed
in the regular household trash. Contact your town

or county officials for information about hazardous
waste disposal in your community.

Содержание IDU

Страница 1: ...Odorox IDU Induct Unit Distributed By Bio Shine dba OdoroxAir Owners Manual 190 Summerhill Road Spotswood NJ 08884 732 25 251 9506 ext 211 odoroxair bio shine com www OdoroxAir com...

Страница 2: ...TS 4 INSTALLATION INSTRUCTIONS 5 OPERATING GUIDELINES 10 CARE INSTRUCTIONS 11 OPTIC REPLACEMENT INSTRUCTIONS 12 TROUBLESHOOTING GUIDE 13 SPECIFICATIONS REPLACEMENT PARTS AND LIMITED WARRANTY 14 LIMITE...

Страница 3: ...ce or cleaning Use generator only for intended use as described in this manual INDOOR USE ONLY Caution For General Ventilating Use Only Do Not Use to Exhaust Hazardous or Explosive Materials and Vapor...

Страница 4: ...cleaner mop or broom Dispose of clothing fabric etc that has come in contact with mercury do not wash Only the individual to clean up the spill should re occupy the space Close the doors to the area...

Страница 5: ...ll the items that were used to pick up the mercury including index cards or cardboard eyedropper contaminated tape paper towels and zipper type bags into the trash bag Carefully remove rubber gloves b...

Страница 6: ...Odorox IDU Hydroxyl Generator Unit 2 One IDU02MD13A Duct Reinforcement Plate Outside 3 One IDU02MD14A Duct Reinforcement Plate Inside 4 One 108 GSK XX 311 Gasket Rubber Foam Adhesive 3 16 THK 1 2 W Gr...

Страница 7: ...duct location Odorox IDUTM Installation STEP 1 Remove the IDU unit from its packaging STEP 2 Remove the optics from the packaging material The optics are fragile use extreme care Do not touch the gla...

Страница 8: ...8 6 EA NUT S8 306 NUT ACORN 8 32 THD BLACK LUSTER COATED STEEL 9 108 IN GSK XX 311 GASKET RUBBER FOAM ADHESIVE 3 16 THK 1 2 W GRAY D C B A A B C D 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 THE INFORMATION CONT...

Страница 9: ...Odorox IDUTM 7 INSTALLATION INSTRUCTIONS...

Страница 10: ...TEP 7 Secure duct reinforcement plates by installing four 8 32 nuts and lock washers provided STEP 8 Install the IDU unit by routing the aluminum chamber through the opening and securing to the plate...

Страница 11: ...urrent sensing relay or pressure switch may be necessary Check with the equipment manufacturer Neutral Line 1 Line 1 Line 2 Dedicated 120 Volt 60 Cycle 15 Amp Circuit Mini HVAC Blower Control 208 Volt...

Страница 12: ...l assuming 2 air changes per hour ACH 85 recirculated air and 9 foot 2 7 m ceilings The guidelines should be adhered to in order to ensure optimal performance and safety Note if the air changes per ho...

Страница 13: ...of the Odorox product can be cleaned in the same manner as the exterior OPTIC CLEANING Cleaning of the optics is recommended to maintain peak processing efficiency Fingerprints smudges dirt dust parti...

Страница 14: ...porcelain end of the optic use your other hand to grip the optic connector Gently wiggle connector while pulling from the optic base Gently pull the optic from the three optic support clips Do not put...

Страница 15: ...ptic has failed Contact local distributor for service Blue LED has failed Contact local distributor for service Internal component failure Contact local distributor for service Optic not functioning R...

Страница 16: ...peration and maintenance of your Odorox product please contact your local Odorox distributor To find a distributor in your area please visit www pyureco com contact or www odorox com contact The PYURE...

Страница 17: ...Road Boynton Beach FL 33426 The PYURE Company 2055 High Ridge Road Boynton Beach FL 33426 Complete below and reverse side Tear along perforation and mail to The PYURE Company within 60 days of purcha...

Страница 18: ...warranty whichever is longer This warranty card does not apply in the following cases a damage to product due to mishandling alteration failure to follow operation maintenance or environmental instruc...

Страница 19: ...e copyrights and other intellectual property rights in the Licensed PYURE Software and any copies thereof You may use a copy of the Licensed PYURE Software with any Odorox product for which you have a...

Страница 20: ...SE PRICE IN NO EVENT SHALL THE PYURE COMPANY S ENTIRE LIABILITY UNDER THIS EULA EXCEED THE PURCHASE PRICE EVEN IF THE LICENSED PYURE SOFTWARE PRODUCT IS DOWNLOADED WITH OTHER THIRD PARTY SOFTWARE FREE...

Страница 21: ...ight 2020 The PYURE Company ODOROX and IDUTM Powered by PYURE TechnologyTM are trademarks of The PYURE Company Boynton Beach FL 33426 USA 190 Summerhill Road Spotswood NJ 08884 732 25 251 9506 ext 211...

Отзывы: