Odorox IDU Скачать руководство пользователя страница 3

Odorox

®

 IDU

TM

1

SAFETY INFORMATION

When using electrical equipment, basic safety precautions should always 
be followed to reduce the risk of fire, electric shock, and injury to persons, 
including the following:

• Read all instructions before using this hydroxyl generator.
• If the generator is covered by a bag or contains packing material when shipped: Remove plastic bag and

packing materials before use.

• To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water.
• WARNING! Always turn electrical power off to the unit prior to maintenance or cleaning.
• Use generator only for intended use as described in this manual.
• INDOOR USE ONLY!
• Caution: For General Ventilating Use Only. Do Not Use to Exhaust Hazardous or Explosive Materials and

Vapors.

• DO NOT attempt to repair or adjust any electrical or mechanical components on this unit. Doing so will void

your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by
authorized personnel only.

• NEVER use detergents, gasoline, furniture polish, paint thinner or other household solvents to clean any part

of the generator.

Use this Hydroxyl Generator only for its intended 
purpose as described in this Owner’s Manual. 

Warning!

Safety Information

PLEASE READ AND SAVE THESE IMPORTANT 
SAFETY INSTRUCTIONS.

IMPORTANT SAFEGUARDS 

Содержание IDU

Страница 1: ...Odorox IDU Induct Unit Distributed By Bio Shine dba OdoroxAir Owners Manual 190 Summerhill Road Spotswood NJ 08884 732 25 251 9506 ext 211 odoroxair bio shine com www OdoroxAir com...

Страница 2: ...TS 4 INSTALLATION INSTRUCTIONS 5 OPERATING GUIDELINES 10 CARE INSTRUCTIONS 11 OPTIC REPLACEMENT INSTRUCTIONS 12 TROUBLESHOOTING GUIDE 13 SPECIFICATIONS REPLACEMENT PARTS AND LIMITED WARRANTY 14 LIMITE...

Страница 3: ...ce or cleaning Use generator only for intended use as described in this manual INDOOR USE ONLY Caution For General Ventilating Use Only Do Not Use to Exhaust Hazardous or Explosive Materials and Vapor...

Страница 4: ...cleaner mop or broom Dispose of clothing fabric etc that has come in contact with mercury do not wash Only the individual to clean up the spill should re occupy the space Close the doors to the area...

Страница 5: ...ll the items that were used to pick up the mercury including index cards or cardboard eyedropper contaminated tape paper towels and zipper type bags into the trash bag Carefully remove rubber gloves b...

Страница 6: ...Odorox IDU Hydroxyl Generator Unit 2 One IDU02MD13A Duct Reinforcement Plate Outside 3 One IDU02MD14A Duct Reinforcement Plate Inside 4 One 108 GSK XX 311 Gasket Rubber Foam Adhesive 3 16 THK 1 2 W Gr...

Страница 7: ...duct location Odorox IDUTM Installation STEP 1 Remove the IDU unit from its packaging STEP 2 Remove the optics from the packaging material The optics are fragile use extreme care Do not touch the gla...

Страница 8: ...8 6 EA NUT S8 306 NUT ACORN 8 32 THD BLACK LUSTER COATED STEEL 9 108 IN GSK XX 311 GASKET RUBBER FOAM ADHESIVE 3 16 THK 1 2 W GRAY D C B A A B C D 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 THE INFORMATION CONT...

Страница 9: ...Odorox IDUTM 7 INSTALLATION INSTRUCTIONS...

Страница 10: ...TEP 7 Secure duct reinforcement plates by installing four 8 32 nuts and lock washers provided STEP 8 Install the IDU unit by routing the aluminum chamber through the opening and securing to the plate...

Страница 11: ...urrent sensing relay or pressure switch may be necessary Check with the equipment manufacturer Neutral Line 1 Line 1 Line 2 Dedicated 120 Volt 60 Cycle 15 Amp Circuit Mini HVAC Blower Control 208 Volt...

Страница 12: ...l assuming 2 air changes per hour ACH 85 recirculated air and 9 foot 2 7 m ceilings The guidelines should be adhered to in order to ensure optimal performance and safety Note if the air changes per ho...

Страница 13: ...of the Odorox product can be cleaned in the same manner as the exterior OPTIC CLEANING Cleaning of the optics is recommended to maintain peak processing efficiency Fingerprints smudges dirt dust parti...

Страница 14: ...porcelain end of the optic use your other hand to grip the optic connector Gently wiggle connector while pulling from the optic base Gently pull the optic from the three optic support clips Do not put...

Страница 15: ...ptic has failed Contact local distributor for service Blue LED has failed Contact local distributor for service Internal component failure Contact local distributor for service Optic not functioning R...

Страница 16: ...peration and maintenance of your Odorox product please contact your local Odorox distributor To find a distributor in your area please visit www pyureco com contact or www odorox com contact The PYURE...

Страница 17: ...Road Boynton Beach FL 33426 The PYURE Company 2055 High Ridge Road Boynton Beach FL 33426 Complete below and reverse side Tear along perforation and mail to The PYURE Company within 60 days of purcha...

Страница 18: ...warranty whichever is longer This warranty card does not apply in the following cases a damage to product due to mishandling alteration failure to follow operation maintenance or environmental instruc...

Страница 19: ...e copyrights and other intellectual property rights in the Licensed PYURE Software and any copies thereof You may use a copy of the Licensed PYURE Software with any Odorox product for which you have a...

Страница 20: ...SE PRICE IN NO EVENT SHALL THE PYURE COMPANY S ENTIRE LIABILITY UNDER THIS EULA EXCEED THE PURCHASE PRICE EVEN IF THE LICENSED PYURE SOFTWARE PRODUCT IS DOWNLOADED WITH OTHER THIRD PARTY SOFTWARE FREE...

Страница 21: ...ight 2020 The PYURE Company ODOROX and IDUTM Powered by PYURE TechnologyTM are trademarks of The PYURE Company Boynton Beach FL 33426 USA 190 Summerhill Road Spotswood NJ 08884 732 25 251 9506 ext 211...

Отзывы: