12
Owner’s Manual
OPTIC REPLACEMENT INSTRUCTIONS
Warning: DISCONNECT the unit from the electrical power source
before performing any maintenance or cleaning on the IDU™ Unit.
Caution: Optics contain Mercury. Read and follow the Safety
Information on pages 2 and 3 of this manual when handling the
optics in the IDU™ unit.
Optic Replacement
Instructions
STEP 1:
Turn MAIN POWER switch to the OFF position
STEP 2 –
Disconnect power from the IDU™ unit
STEP 3 –
Remove optics following these instructions:
Caution: Use clean powder free latex gloves and eye protection when handling the optics in this unit
• With a firm grip on the upper porcelain end of the optic, use your other hand to grip the optic connector.
• Gently ‘wiggle’ connector while pulling from the optic base.
• Gently pull the optic from the three optic support clips
(Do not put any pressure on the side of the optic
without support).
STEP 4 –
Install new optic following these instructions:
• Remove new optic from packaging and gently insert into the three optic clips.
• With a firm grip on the upper porcelain end of the optic, use your other hand to grip the optic connector.
• Gently connect the optic connector to the optic.
Note: Optic connector is keyed with the optic base and will connect in one direction onl
y
• Ensure optic connector and optic base are firmly pressed together.
STEP 5 –
Re-install the IDU™ unit inside the duct.
STEP 6 –
Reconnect power to the IDU™ unit.
STEP 7 –
Test unit for proper operation.
Содержание IDU