Display Menus and Controls 5 - 13
Time Mode:LUTC Local Offset:-08 hrs
≡
Internal Offset:
+
00000 ns
•
Use the arrow keys to select positive (+) or negative (-) Internal Offset.
•
Press the Enter key to accept the selected Internal Offset polarity.
•
Use the arrow and numeric keys to select the nanoseconds of Internal Offset.
•
Press the Enter key to accept the selected nanoseconds of Internal Offset.
Note: The Operation Mode may temporarily change to Coasting when the Internal
Offset is changed. Should this occur the unit would correct itself in approximately ten
minutes.
5.4.1.5
Time Code Format Selection
The unit is capable to provide one of the following user selected time code output
signals: IRIG-A, IRIG-B, or IRIG-G.
•
Press key 1 until Time Menu 3 of 5 is selected (
Time Code Selection
).
Time Code Format:IRIG A
≡
•
While viewing the Time Menu 3 of 5 screen, press the Edit key.
•
Press the arrow keys until the desired Time Code Format (
IRIG A, IRIG B,
or
IRIG G
) is flashing
•
Press the Enter key to accept the selected Time Code Format.
5.4.1.6
Daylight Saving Time Status Selection
The user can enable or disable the manual Daylight Saving Time function. When
enabled, the unit to adds or subtracts one hour at 02:00:00 Local Time on the user
selected day of the current month. Daylight Saving Time is only applicable when UTC
or GPS with Local Time Offset is selected as time reference (LUTC or LGPS).