Odetics
Telecom
GPStar
plus
Model 365
365-8006
Display Menus and Controls 5 - 11
Change the Synchronization mode from Manual Time to normal as follows:
•
Press key 1 until Time Menu 1 of 5 is selected (
Time, Date, Status, Satellites
).
•
While viewing the Time Menu 1 of 5 display screen, press the Edit key.
Manual Time Mode
Enabled
≡
•
Press the arrow keys until
Disabled
is flashing (selects normal synchronization).
•
Press the Enter key to change to normal synchronization.
5.4.1.2
Time Reference Selection
Under normal operating conditions, the unit’s internal GPS receiver provides the time
and date. The time and date can be referenced to either UTC or GPS time.
In order to synchronize to either UTC or GPS time, the unit must operate in the normal
synchronization mode; that is:
not in the Manual Time mode
.
Select time reference UTC or GPS as follows:
•
Press key 1 until Time Menu 2 of 5 is selected (
Time Mode, Local Offset,
Internal Offset
).
•
While viewing the Time Menu 2 of 5 screen, press the Edit key.
Time Mode:
LUTC
Local Offset:-08 hrs
≡
Internal 00000 ns
•
Press the arrow keys until desired reference Time Mode (
GPS, UTC, LGPS,
or
LUTC
is flashing.
•
Press the Enter key to accept the selected reference Time Mode.
•
Press the Menu key to exit the edit mode, or proceed to the next paragraph.