Connecting a flat panel display
The PC–600 is factory configured and programmed for a 640 x 480 CRT
monitor. If you wish to use a flat panel, you must reprogram the video
BIOS with the appropriate flat panel driver. To reprogram your video
BIOS refer to
Programming the video BIOS
in this chapter. Note that
both 3V and 5V flat panels are supported. Jumper W6 selects the flat
panel voltage. Flat panel displays are connected using a 40-pin 2mm
connector at J14.
The connector at J16 provides the control signals for back-light for flat
panels. The jumper at W9 selects 5V or 12V for back-light voltage.
Tables 11–2, 11–3, and 11–4 show the jumper settings and connectors for
flat panels.
The Utilities zip file contains text files for each of the supported flat
panels (see page 145). These text files include wiring diagrams specific to
individual flat panels. Refer to the specific text file associated with your
flat panel to build an interface cable, and to determine the correct settings
for the flat panel jumpers.
To connect a flat panel to the PC–600 you will need the following
equipment (or equivalent):
PC–600 CPU card
Flat panel
Custom flat panel to PC–600 cable
Flat panels requiring bias voltage
Some flat panels require a bias voltage. To determine if your flat panel
requires bias voltage refer to your flat panel information. If your flat
panel requires a bias voltage, refer to the manufacturer’s documentation
for procedures on supplying the proper bias voltage.
WARNING!
Since improper voltage levels can severely damage the flat
panel, make sure the bias voltage is correct before the flat
panel is connected to the PC–600.
89
Содержание PC-600
Страница 23: ...Figure 2 1 PC 600 connector and jumper diagram 23 ...
Страница 24: ...Figure 2 2 PC 600 center to center hole dimensions thousandths 24 ...
Страница 25: ...Figure 2 3 PC 600 center to center hole dimensions millimeters 25 ...
Страница 150: ...Table C 3 Miscellaneous part numbers Product Description Octagon p n AT battery Calendar clock battery backup 3186 150 ...