Chapter 18: Troubleshooting
If your system is not working properly, check the following items.
No system LED activity
If there is no LED activity, check the following:
Turn the “S” switch Off.
Check all power connections to the 5266 card.
Measure the supply voltage at the J11 power connector and verify that the
voltage at the 5266 card is +5V (+/–0.25V).
Make sure your power module pr5V (+/–0.25V) and at least 10A of
current (to meet inrush requirement).
No CRT or flat panel video
If the LEDs appear to be functioning properly, but there is no video activity, check
the following:
Turn the “S” switch Off.
If using a CRT monitor, check the cable and connections going from the J6
connector to the monitor.
If using a flat panel display, check the following:
Check the power and cables going to the flat panel display.
Make sure that the power module has enough current capacity to power both
the 5266 card and the flat panel.
Ensure you have entered the proper settings for your flat panel in BIOS Setup.
If an analog monitor is not present or is not displaying the video data correctly,
the system can be booted via the serial console by doing the following:
1. Turn the “S” switch Off and the “V” switch On.
2. Connect the COM port of a host computer running HyperTerminal or some
other terminal software to COM1 on the 5266 using a serial console (see
page 52.) The serial port settings on the host computer should be 115.2K
baud, 8, N, and none.
3. Power up the 5266; it will boot using the serial console interface.