Figure 5–2 W2 jumper pin locations
2060
W3
1 3
2 4
2 4
W2
1 3
W1
Setup menu for COM ports
The I/O Device Configuration submenu allows you to set the I/O configurations.
You must enable COM2 and select the interface you are using. You must also set
the jumpers for the interface (see table above).
PhoenixBIOS Setup Utility
Advanced
I/O Device Configuration
Item Specific Help
Serial port A:
Serial port B:
Interface:
Parallel port:
Mode:
Base I/O address:
Interrupt:
DMA channel:
[3F8/IRQ4]
[Disabled]
[RS-232]
[Enabled]
[Bi-directional]
[378]
[IRQ 7]
[DMA 1]
F1 Help ^v Select Item -/+ Change Values F9 Setup Defaults
Esc Exit <> Select Menu Enter Select > Sub-Menu F10 Save and Exit
Function and use of serial ports
Mating receptacle
Use a 2060 HDC-18-SBC-Multiport cable to connect the COM ports to external
serial equipment. The two COM connectors on the HDC-18-SBC-Multiport cable
are DB–9 female connectors that plug directly into a 9-pin PC serial cable. See
pages 26 and 27 for information on the 2060 HDC-18-SBC-Multiport cable. Use an
RS–422/485 cable for connecting RS–422 and RS–485 devices, through the J7
connector.
Note
See
pages
26 and 27, and Appendix A – Mating connectors for mating information.