Page 26 of 52
7.3
Time program for hot water
Time program
Hot water
Description
Hot water
time program
The time of day at which the hot water charging at normal or
energy saving temperature takes place is set here.
Hot water anti Legionella
time program
The time at which the increased Legionella protection tem-
perature is active is set here.
(Depending on the type of system, the heating to Legionella
protection temperature will (partly) done by the auxiliary
heater - but only when the heat pump has switched off via
the max. flow temperature limiter - i.e. a higher temperature
cannot be reached.)
Settings procedure:
1.
Press
the adjustment knob in the main
display > the main menu appears
2.
Select the Hot Water Circuit by
turning
the
adjustment knob and confirm by
pressing
the knob. > the temperature image for the
hot water circuit appears.
3.
In hot water temperature image, select the
hot water menu by
pressing
the adjust-
ment knob.
4.
By
turning
the adjustment knob, select
Settings
in the hot water menu and con-
firm this by
pressing
the knob.
5.
By
turning
the adjustment knob, select
time program
and confirm this by
pressing
the knob.
7.
By
turning
the adjustment knob, select
the
desired
time program
and confirm this by
pressing
the knob. > Adjust the time pro-
gram according to the description (see Sec-
tion 7.1)
HOT WATER
Hot water time programm
Legionella programm
ESC
ENTER
ESC
ENTER
Time programm
Setpoint
Configuration
HOT WATER
HEAT PUMP
ESC
ENTER
Main menu
HEATING CIRCUIT 1
HEATING CIRCUIT 2
HOT WATER
Heating m ode
OCHSNER OTE
MENU
Sa 05.08.2017
08:10
ESC
MENU
HOT WATER
HOT WATER
Operation mode
Operational data
Settings
Relay test
ESC
ENTER
1
3
5
2
4