BA OCHSNER AQUA TERRA_EN_V01.1.docx
Page 25 of 72
Code
No. Logfile
Error description
Possible cause/ remedy
115
Er 01: Hot water sensor defect
Replace sensor
116
Er 10: Outside sensor defect
Replace sensor
117
Er 14: Mixer sensor defect
Replace sensor
124
Er 20: TWR sensor defect
Replace sensor
120
Er 22: Switch-off sensors TWR/TPM de-
fect
Replace sensor
136
Er 23: TPV sensor defect
Replace sensor
118
Er 24: Buffer sensor defect
Replace sensor
114
Er 29: TWV sensor defect
Replace sensor
11
11
Er 30: Phase monitor
Monitoring via start-up current limiter KS01
(display of type of alarm via blink sequence of
the red LED)
134
Er 32: THG sensor defect
Replace sensor
138
Er 33: High pressure sensor defect
Check sensor
137
Er 34: Low pressure sensor defect
Check sensor
5
5
Er 36: High pressure
Insufficient heat distribution, circulation
pump defect, valve closed / air in the system,
check the hydraulics
18
18
Er 37: Low pressure
Insufficient heat source, insufficient refriger-
ant, expansion valve, check the refrigerant
circuit (OCHSNER)
16
16
Er 38: Hot gas
Expansion vessel, insufficient refrigerant, set
value too high, check the refrigerant circuit
(OCHSNER)
10
10
Er 39: Motor protection compressor
Overload, heat source temperature too high,
Check: Compressor in cooling circuit
(OCHSNER)
8
8
Er 42: Frost protection in heating sys-
tem
Insufficient heat distribution, circulation
pump defect, valve closed / air in the system,
check the buffer pump or the hydraulics
Er 46: TSG sensor defect
Replace sensor
9
9
Er 47: De-icing malfunction
Insufficient de-icing energy, evaporator/sen-
sor, check the refrigerant circuit (OCHSNER)
129
129
Er 48: TQE sensor defect
Replace sensor
130
130
Er 49: TQA sensor defect
Replace sensor
12
12
Er 50: Expansion valve
Check the function of the EEV (OCHSNER)
1
1
Er 56: Flow rate of heat source
Flow rate too low, lack of heat source energy,
check source pump/filter
2
2
Er 57: Frost protection heat source
Insufficient heat source energy, heat source
temperature to low, check heat source, check
heat source pump/filter, clean water filter,
ground water pump defect
3
3
Er 58: Motor protection heat source
Overload, check motor protection, wiring to
motor/fan, check TK
143
143
Er 59: Sensor breakage TWV + TWR
Check sensor
144
Er 60: Sensor breakage TQA + TQE
Check sensor
42
42
Er 71: Bus malfunction, room remote
control
Check eBus wiring
30
30
Er 80: Address WEZ 1
Check addressing
31
31
Er 81: Address WEZ 2
Check addressing
32
32
Er 82: Address WEZ 3
Check addressing
33
33
Er 83: Address WEZ 4
Check addressing
Содержание AQUA 54
Страница 2: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 2 of 72 ...
Страница 44: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 44 of 72 12 16 Electrical circuit diagrams ...
Страница 45: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 45 of 72 ...
Страница 46: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 46 of 72 ...
Страница 47: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 47 of 72 ...
Страница 48: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 48 of 72 13 Disassembly assembly panel ...
Страница 51: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 51 of 72 2 screws on the back remove 4 mm Allen key ...
Страница 56: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 56 of 72 The two lateral wooden beams screw Hold with spanner ...
Страница 58: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 58 of 72 14 Declaration of Conformity ...
Страница 59: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 59 of 72 ...
Страница 60: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 60 of 72 ...
Страница 61: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 61 of 72 ...
Страница 69: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 69 of 72 ...
Страница 70: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 70 of 72 ...
Страница 71: ...BA OCHSNER AQUA TERRA_EN_V01 1 docx Page 71 of 72 ...