BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08.docx
Page 66 of 92
Distance-dependent sound
pressure level (audible sound) of
outdoor units at
nominal
compressor frequency (at partial
load)
and installation in a free field
Distance 1 metre
dB(A)
52
54
56
56
Distance 5 metres
dB(A)
38
40
42
42
Distance 10 metres
dB(A)
32
34
36
36
Air intake temperature
Heating mode min.
°C
-20
-20
-20
-20
Heating mode max.
°C
35
35
35
35
Cooling mode min.
°C
15
15
15
15
Cooling mode max.
°C
45
45
45
45
Electrical values, outdoor unit
Compressor phases/nominal
voltage/frequency
~/V/Hz
1/220-240/50
3/380-
400/50
1/220-
240/50
Operating power consumption
A7/W35
A
4.5
8.8
Operating power consumption
(max.) A-7/W55
A
7.4
12.2
Starting current, compressor
A
10.5
15
15
10
Starting current, compressor with
stalled armature
A
20
25
20
32
Starting current (charging of DC
capacitor)
A
45
<35
Fuse protection tripping curve "C"
A
16
16
20
32
Fan (max.)
W
35
70
90
90
Controller PCB, outdoor unit
W
150
150
150
150
Electrical values, indoor unit
Nominal voltage, electric booster
heater
V/Hz
2/380-
400/50 or
1/220-
240/50
3/380-400/50 or 1/220-240/50
Output, electric booster heater
kW
5.9
(2.95/2.95)
8.8
(2.95/2.95/
2.95)
8.8
(2.95/2.95/2.
95)
8.8
(2.95/2.95/2.
95)
Fuse protection, mains voltage
A
3 x C16
3 x C16
3 x B16
3 x B16
Nominal voltage, indoor unit
controller
~/V/Hz
1/220-240/50
Fuse protection, indoor unit
controller
A
6.3
6.3
6.3
6.3
Heating water
Minimum flow rate
l/h
400
715
950
950
Nominal flow rate
l/h
800
1430
1900
1900
Max. flow temperature
°C
55
55
55
55
Min. temperature
water outlet, cooling mode
Without buffer tank
°C
12
12
12
12
With buffer tank
°C
7
7
7
7
Содержание AIR BASIC 109
Страница 2: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 2 of 92...
Страница 22: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 22 of 92...
Страница 34: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 34 of 92 Dimensions Figure 37 T200 dimensions...
Страница 78: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 78 of 92 11 4 Declaration of conformity...
Страница 79: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 79 of 92...
Страница 80: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 80 of 92...
Страница 81: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 81 of 92...
Страница 82: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 82 of 92 11 5 ERP Data...
Страница 83: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 83 of 92...
Страница 84: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 84 of 92...
Страница 85: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 85 of 92...
Страница 86: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 86 of 92...
Страница 87: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 87 of 92...
Страница 90: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 90 of 92...
Страница 91: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 91 of 92...