Use and Maintenance Manual

PAPI

25

ADJUSTMENTS AND MAINTENANCE

Before carrying out any intervention on the device, cut off all external power sources and 

place appropriate work-in-progress warnings on the systems.

Wait for the discharging time (at least 5 min) and check using appropriate instruments that 

there are no residual energies before accessing the electrical equipment.

To minimize operations, always pay the greatest attention to handling and storage of devices and carry out installation 

procedures with extreme precision.

4.1 

Scheduled maintenance

In accordance with the suggestions contained in the document FAA AC 150 5340-30, PAPI 401 fixtures must be 

subjected to regular maintenance.

In order to assure the proper functioning of the fixture and the maximum duration of the operating lifetime of the 

device all the checks and periodical audits must be carried out and, if necessary, the necessary corrective procedures 

must be activated to restore and ensure operative safety levels foreseen by the standards.

Do not let running devices not properly maintained or fixtures presenting signs of damage 

or fault.

Each maintenance operation carried out on the devices must be noted on the maintenance register.

Frequency

Description

every day

Check of the normal operation of the fixture.

monthly

Command control.

Check of the general conditions to identify any damages caused by service vehicles or 

aircrafts

External cleaning of the protective glass and, if necedssary, of the lens and of the filters.
Check of the mechanical parts to identify any damages.
Check the status of the protective devices (dischargers).
Search for any damage caused by seepage of water and by insect infestations
Search for presence of rodents.
Verification of the alignment and pointing of the units

every 4 

months

Integrity check of the OCS buffer zone (obstacle-free) in approach direction.

every 6 

months

Verification of the insulation resistance of the underground cables.
Verification of the earth resistance of the system.

every year

Check the stability of the civil works.

unscheduled

Replacement of fixtures presenting breakdowns or malfunctions.
Check of the electrical connections and of the isolation degree of the system (to be carried 

out during intervention requiring the removal of the fixture cover).
Check of the mounting gaskets (to be carried out during intervention requiring the removal of 

the fixture cover).
Check of the integrity of the electric cables (to be carried out during intervention requiring the 

removal of the fixture cover).
Removal of snow (when necessary).

Содержание PAPI

Страница 1: ...ntenance Manual ocem EN 29acdb84 d07b 41e6 b3b5 3049609cfc5f HALO Precision Approach Path Indicator FIXTURE FOR AIRPORTS HELIPORTS HALOGEN LAMPS LOW MANAGEMENT COSTS LOW MAINTENANCE UT MT 0970_1 0_02...

Страница 2: ...Contact us OCEM AT 1 1 39 051 66 56 611 1 2 info ocem com Editions Revision Date Notes 1 0 02 08 2022 First edition...

Страница 3: ...ication 9 1 11 Photo biological risk 10 2 FIXTURE DESCRIPTION 2 1 General characteristics 11 2 2 Article number 15 2 3 Wiring 16 2 4 Method of calculation of the installation parameter 16 3 INSTALLATI...

Страница 4: ...Page intentionally left blank UT MT 0970_1 0_02 08 2022 EN Use and Maintenance Manual PAPI 4...

Страница 5: ...talian Civil Aviation Authority ENAC Airport Construction Regulation Immediately check for visible damages of the container Carefully remove the device and check for visible damages Check the presence...

Страница 6: ...e precautions safeguard the personal security of everyone who work on and or are in proximity of the equipment and of the relative supply circuits The failure to comply with the instructions in partic...

Страница 7: ...out maintenance or repair 1 5 Definition of operator All operations on devices and on its internal parts must be performed by professional staff properly formed and aware of the risks connected with t...

Страница 8: ...the components in the shortest possible time without prejudice to the fact that for the so called commercial components and more generally for the components supplied by third party manufacturers wil...

Страница 9: ...respondence received by the Supplier or in any case assimilated or gained during the conclusion of the Contract of sale Any right regarding intellectual and industrial property connected to equipment...

Страница 10: ...emitted by the fixture reaching even high levels of intensity can be harmful not only to those who use the light fixture locally but for anyone within the light beam range The optical radiation issue...

Страница 11: ...sh signalling Four light PAPI the system in use in commercial and military airports consists of 4 units each equipped with 2 or 3 lamps 200 W current powered in environments with temperatures between...

Страница 12: ...oncrete bases properly dimensioned The PAPI is compliant with the rules ICAO Annex 14 Volume I Paragraph 5 3 5 and Aerodrome Design Manual Part 4 CASA Manual of Standards Part 139 NATO Stanag 3316 ENA...

Страница 13: ...al actual elevation of the optical axis QC Actual elevation of the base The example shows the main measures to be evaluated for proper design of the PAPI or A PAPI system The installation of a PAPI or...

Страница 14: ...are available for installation pointing and fixtures adjustment a template 1 for the positioning of the ground anchorage diversified for the 2 or 3 lamps model the threaded anchorage flanges 2 2 11 GA...

Страница 15: ...lass always present Flexible sheathing for power cable protection Anti condensation heater NATO system configurable only with 3 lamps unit Heliport system ICAO configurable only with 2 lamps unit Lamp...

Страница 16: ...6 6 A In case of double PAPI system installed both right and left of the landing runway or of the helipad each branch should be powered by a different series circuit Thus configured the failure of a...

Страница 17: ...approaching The actual distance of the optical axis DO of the unit in relation to the threshold can be calculated with the following formula distances expressed in m The actual elevation of the optica...

Страница 18: ...Page intentionally left blank UT MT 0970_1 0_02 08 2022 EN Use and Maintenance Manual PAPI 18...

Страница 19: ...clean maintained and if necessary replaced as soon as their visibility is affected The light sources must be positioned according to the legislative provisions near the runway oriented towards the ap...

Страница 20: ...ead turns Screw the coupling on the plate until tightening Insert the ring inside the seat and screw the nut on the frangible coupling without tightening make maximum 3 turns Insert the ring inside th...

Страница 21: ...o specifications FAAand ICAO At the end of installation check the proper alignment of the fixture In case of incorrect positioning optical misalignments of light beams may occur The installer is the s...

Страница 22: ...0970_1 0_02 08 2022 EN Use and Maintenance Manual PAPI 22 i standard runway large runway with ILS 1 2 30 2 50 2 25 2 42 2 2 50 2 83 2 45 2 75 3 3 10 3 17 3 15 3 25 4 3 30 3 50 3 35 3 58 allowed toler...

Страница 23: ...INSTALLATION UT MT 0970_1 0_02 08 2022 EN Use and Maintenance Manual PAPI 23...

Страница 24: ...ixtures can emit light beams in the visible and infrared spectrum causing potential danger to eyesight Before the commissioning of the system it is necessary to submit it to an inspection by the compe...

Страница 25: ...rried out on the devices must be noted on the maintenance register Frequency Description every day Check of the normal operation of the fixture monthly Command control Check of the general conditions...

Страница 26: ...least 5 minutes and check using appropriate instruments that there are no residual energies before accessing the electrical equipment Every time that the fixture body is opened all cables must be chec...

Страница 27: ...t there are no residual energies before accessing the electrical equipment Clean the external surface of the front protective glass with neutral and non abrasive products using clean clothes The exter...

Страница 28: ...before accessing the electrical equipment The replacement procedure of the lamp is valid for all the light sources Lamp lifetime depends on the actual use conditions working time brightness level and...

Страница 29: ...the lamp during insertion Do not touch the halogen lamp with bare hands If the lamp is touched with bare hands before proceeding with installation clean the bulb with a lens cleaning wipe soaked in i...

Страница 30: ...check using appropriate instruments that there are no residual energies before accessing the electrical equipment The complete support diversified depending on the type and position fixed installatio...

Страница 31: ...reakable coupling element Rotate counterclockwise and remove the support of the fastening flange Screw the ring nut to the frangible coupling for about 2 thread turns Screw the coupling on the plate u...

Страница 32: ...e lower nut to the correct height previously detected Position the unit on the supports and put the spherical washers Tighten the upper locking nuts Check the proper alignment of the fixture see the r...

Страница 33: ...ight emission from a single unit Fault on the connection cable between transformer and unit Access the connection box and disconnect the cable that supply the unit using suitable tools check the prope...

Страница 34: ...ced light flow Burnt lamp Disconnect the supply cable of the unit ATTENTION do not perform maintenance activities with powered devices Remove the external cover of the fixture Replace the lamp The uni...

Страница 35: ...MAINTENANCE PAPI 35 UT MT 0970_1 0_200223 EN Use and Maintenance Manual 4 7 Spare parts Always check the version of the fixture installed and the accessories present PAPI fixture A Supports B Light un...

Страница 36: ...0010 Increased leg with breaking groove L 145 mm previous models 334 5900 Increased leg with breaking groove L 195 mm previous models 334 5905 Increased leg with breaking groove L 245 mm previous mod...

Страница 37: ...alid 810 2001 13 Lens locking ring always valid 321 4110 14 Red tempered filter C H 318 4140 Red tempered filter military use M 318 4150 15 Reflector with lamp holder small plate C H 162 4040 Reflecto...

Страница 38: ...ion Template of masonries for heliports 2 lamps previous models 332 3430 Installation Template of masonries 3 lamps previous models 332 3420 24 Base plate for L 867 base 2 entrances with gasket and pl...

Страница 39: ...Contact us OCEM AT 4 3 39 051 66 56 611 4 4 info ocem com...

Страница 40: ...ocem OCEM AT a division of ENERGY TECHNOLOGY S r l Via della Solidariet 2 1 40056 Valsamoggia Bologna Italy HALO Precision Approach Path Indicator UT MT 0970_1 0_02 08 2022 EN...

Отзывы: