SAFETY:

1.   Turn off all switches and unplug all power 

cords from outlet or power source before 
performing maintenance.

Refugium Setup With Refugium 
Light (not included)

1.   Remove left and right filtration covers.

2.  Remove overflow tray and filter cartrige 

from center filter chamber.

3.  Once the BioCube aquarium is fully set     

up and ready to support livestock, add 
substrate and macroalgae to the refugium 
chamber. Replace overflow tray, filter 
cartridge and  left and right filtration covers.

Refugium Light Installation   
(Figure C7)

1.   Locate window on the back of the BioCube HQI.

2.  Clean area around the illumination window 

with a dry cloth to remove any dust,         
salt or water.

3.  Follow instructions included with the 

refugium light to mount to BioCube HQI.

REFUGIUM SETUP AND REFUGIUM

LIGHT INSTALLATION

FIGURE C7

BioCube Filtration Stages   
(Figures C8–C10)

1.   Water flows from aquarium into the surface 

and bottom intakes into chamber 1 where 
some enters the protein skimmer        
(Figure C8). The protein skimmer removes 
many harmful organic materials from        
the water.

2.  From chamber 1, water flows over the top   

of and through the filter cartridge into      
the refugium in chamber 2 (Figure C9).   
Live macroalgae and live rock in the 
refugium remove excess nutrients and add 
oxygen to the water while helping stabilize            
the pH level.

3.  From the refugium, water flows into 

chamber 3 through the sponge filter        
and into the water pump (Figure C10).     
The water pump then forces the water 
through the flexible tubing and back into 
the aquarium through the discharge nozzle.

BIOCUBE FILTER OPERATION

FIGURE C8

FIGURE C9

FIGURE C10

16

17

Содержание BioCube HQi

Страница 1: ...RRANTIES UNDER THIS LIMITED WARRANTY ALL SUCH WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY OCEANIC I...

Страница 2: ...tt 14 000K double ended metal halide Cooling Fans 38 mm 4 000 RPM Pump Flow Rate 243 gph 920 L H Page 4 Important Safety Instructions Page 6 Grounding Page 7 BioCube HQI Assembly and Setup Instruction...

Страница 3: ...ause algae growth 4 Keep aquarium in a well ventilated area away from a heating or cooling vent 5 Do not place near electronic components and systems i e TV stereo systems etc IMPORTANT SAFETY INSTRUC...

Страница 4: ...e like extending from the adapter must be fastened to a permanent ground such as a grounded outlet box 1 Plug temporary adapter into two pole outlet Figure A4 2 Insert screw through rigid ear on tempo...

Страница 5: ...ion Cover 2 Right Filtration Cover 3 Glass Canopy 4 Filter Cartridge 82105 5 Overflow Tray 6 Output Elbow Attachment 7 Flexible Tubing 8 Water Pump 82007 9 Output Discharge Nozzle 10 BioCube Glass Aqu...

Страница 6: ...tion 1 Collection Cup Lid 2 Collection Cup 3 Reaction Chamber Top 4 Suction Cup 5 Airstone 6 Reaction Chamber Assembly 7 Airline Tubing 7 8 Air Pump 9 Inline Air Flow Valve 10 Check Valve PROTEIN SKIM...

Страница 7: ...wall between chambers 1 and 2 NOTE if skimmer is in correct position the right filtration cover will fit properly Collection Cup Assembly Figure C3 1 Place collection cup on top of reaction chamber P...

Страница 8: ...Add substrate rocks and d cor to the aquarium 2 Prepare saltwater for aquarium making sure water is at room temperature 3 Slowly add water to the aquarium Make sure to fill aquarium to the lower edge...

Страница 9: ...ith the refugium light to mount to BioCube HQI REFUGIUM SETUP AND REFUGIUM LIGHT INSTALLATION FIGURE C7 BioCube Filtration Stages Figures C8 C10 1 Water flows from aquarium into the surface and bottom...

Страница 10: ...Aqualight HQI ASSEMBLY AND SETUP INSTRUCTIONS AQUALIGHT HQI PARTS DIAGRAM 1 18 19 16 15 17 2 3 4 5 6 7 8 9 10 14 11 12 13 18 19...

Страница 11: ...ket Connection B with female connection knob using height adjustment knob 2 Screw height adjustment knob through Connection B and into Connection A 3 Adjust and secure connection Safety Precautions 1...

Страница 12: ...n connector on fixture 2 Attach cooling fan connector to cooling fan adaptor BALLAST AND COOLING FAN SETUP MALE FEMALE Double ended HQI Metal Halide Lamp Connector Double ended HQI Metal Halide Ballas...

Страница 13: ...HQI metal halide lamp with fingers as the oils may damage the lamp If contact is made with the lamp use a clean soft dry cloth to remove any fingerprints from the lamp before use LAMP REPLACEMENT Lam...

Страница 14: ...s BIOCUBE MAINTENANCE con t Filter Cartridge Overflow Tray Pump Housing Pump Impeller Ceramic Shaft Impeller Cover Sponge Filter FIGURE C12 FIGURE C13 FIGURE C14 t i l t u p Pull away WARNING 1 Make s...

Отзывы: