background image

BIOCUBE HQI PARTS DIAGRAM

1

3

2

4

9

5

6

10

8

7

12

11

13

BIOCUBE HQI

PARTS IDENTIFICATION

  

 Part # 

Description 

Item #

 

1   

Left Filtration Cover

  2   

Right Filtration Cover 

 

  3   

Glass Canopy 

  4   

Filter Cartridge 

82105

  5   

Overflow Tray

  6   

Output Elbow Attachment

  7   

Flexible Tubing

  8   

Water Pump 

82007

  9   

Output Discharge Nozzle

 10   

BioCube Glass Aquarium

  11   

BioCube Protein Skimmer 

(see pages 10 and 11 for parts/identification)

 

82053

 12   

Refugium Strainer

 13   

Sponge Filter

8

9

Содержание BioCube HQi

Страница 1: ...RRANTIES UNDER THIS LIMITED WARRANTY ALL SUCH WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY OCEANIC I...

Страница 2: ...tt 14 000K double ended metal halide Cooling Fans 38 mm 4 000 RPM Pump Flow Rate 243 gph 920 L H Page 4 Important Safety Instructions Page 6 Grounding Page 7 BioCube HQI Assembly and Setup Instruction...

Страница 3: ...ause algae growth 4 Keep aquarium in a well ventilated area away from a heating or cooling vent 5 Do not place near electronic components and systems i e TV stereo systems etc IMPORTANT SAFETY INSTRUC...

Страница 4: ...e like extending from the adapter must be fastened to a permanent ground such as a grounded outlet box 1 Plug temporary adapter into two pole outlet Figure A4 2 Insert screw through rigid ear on tempo...

Страница 5: ...ion Cover 2 Right Filtration Cover 3 Glass Canopy 4 Filter Cartridge 82105 5 Overflow Tray 6 Output Elbow Attachment 7 Flexible Tubing 8 Water Pump 82007 9 Output Discharge Nozzle 10 BioCube Glass Aqu...

Страница 6: ...tion 1 Collection Cup Lid 2 Collection Cup 3 Reaction Chamber Top 4 Suction Cup 5 Airstone 6 Reaction Chamber Assembly 7 Airline Tubing 7 8 Air Pump 9 Inline Air Flow Valve 10 Check Valve PROTEIN SKIM...

Страница 7: ...wall between chambers 1 and 2 NOTE if skimmer is in correct position the right filtration cover will fit properly Collection Cup Assembly Figure C3 1 Place collection cup on top of reaction chamber P...

Страница 8: ...Add substrate rocks and d cor to the aquarium 2 Prepare saltwater for aquarium making sure water is at room temperature 3 Slowly add water to the aquarium Make sure to fill aquarium to the lower edge...

Страница 9: ...ith the refugium light to mount to BioCube HQI REFUGIUM SETUP AND REFUGIUM LIGHT INSTALLATION FIGURE C7 BioCube Filtration Stages Figures C8 C10 1 Water flows from aquarium into the surface and bottom...

Страница 10: ...Aqualight HQI ASSEMBLY AND SETUP INSTRUCTIONS AQUALIGHT HQI PARTS DIAGRAM 1 18 19 16 15 17 2 3 4 5 6 7 8 9 10 14 11 12 13 18 19...

Страница 11: ...ket Connection B with female connection knob using height adjustment knob 2 Screw height adjustment knob through Connection B and into Connection A 3 Adjust and secure connection Safety Precautions 1...

Страница 12: ...n connector on fixture 2 Attach cooling fan connector to cooling fan adaptor BALLAST AND COOLING FAN SETUP MALE FEMALE Double ended HQI Metal Halide Lamp Connector Double ended HQI Metal Halide Ballas...

Страница 13: ...HQI metal halide lamp with fingers as the oils may damage the lamp If contact is made with the lamp use a clean soft dry cloth to remove any fingerprints from the lamp before use LAMP REPLACEMENT Lam...

Страница 14: ...s BIOCUBE MAINTENANCE con t Filter Cartridge Overflow Tray Pump Housing Pump Impeller Ceramic Shaft Impeller Cover Sponge Filter FIGURE C12 FIGURE C13 FIGURE C14 t i l t u p Pull away WARNING 1 Make s...

Отзывы: