Protein Skimmer Assembly    
(Figure C1)

1.   Insert airline tubing into air pump using   

end that has just 6" before the inline          
air flow valve.

2.  Remove reaction chamber top from 

reaction chamber and insert the other     
end of the airline tubing through the hole   
at the bottom of the reaction chamber.

3.  Attach the airstone to the end of the    

airline tubing and pull it back through     
until the airstone is at the bottom               
of the reaction chamber.

4.  Reassemble all parts of the protein 

skimmer, except for the collection cup.

Protein Skimmer Placement    
(Figure C2)

1.   Using hanging clip on reaction chamber 

top, hang protein skimmer on the wall 
between chambers 1 and 2. 

NOTE:

 if 

skimmer is in correct position, the right 
filtration cover will fit properly.

Collection Cup Assembly      
(Figure C3)

1.   Place collection cup on top of reaction 

chamber. Pull airline tubing through the hole 
on the back of the right filtration cover, 
making certain that airflow is not restricted 
when the right filtration cover is on.

Protein Skimmer Startup    

1.   Once water has been added (page 23),   

plug in pump. Adjust airflow adjustment 
nozzle so that bubbles stay just above      
the reaction chamber.  

2.  When collection cup fills, remove             

and dispose of waste material by rinsing 
with warm water.

BIOCUBE PROTEIN SKIMMER SETUP

BIOCUBE PROTEIN SKIMMER SETUP

(con't)

Reaction Chamber Top

Airstone

Reaction Chamber

6" Length of Airline Tubing

Inline Air Flow Valve

FIGURE C2

FIGURE C1

FIGURE C3

12

13

Содержание BioCube HQi

Страница 1: ...RRANTIES UNDER THIS LIMITED WARRANTY ALL SUCH WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY OCEANIC I...

Страница 2: ...tt 14 000K double ended metal halide Cooling Fans 38 mm 4 000 RPM Pump Flow Rate 243 gph 920 L H Page 4 Important Safety Instructions Page 6 Grounding Page 7 BioCube HQI Assembly and Setup Instruction...

Страница 3: ...ause algae growth 4 Keep aquarium in a well ventilated area away from a heating or cooling vent 5 Do not place near electronic components and systems i e TV stereo systems etc IMPORTANT SAFETY INSTRUC...

Страница 4: ...e like extending from the adapter must be fastened to a permanent ground such as a grounded outlet box 1 Plug temporary adapter into two pole outlet Figure A4 2 Insert screw through rigid ear on tempo...

Страница 5: ...ion Cover 2 Right Filtration Cover 3 Glass Canopy 4 Filter Cartridge 82105 5 Overflow Tray 6 Output Elbow Attachment 7 Flexible Tubing 8 Water Pump 82007 9 Output Discharge Nozzle 10 BioCube Glass Aqu...

Страница 6: ...tion 1 Collection Cup Lid 2 Collection Cup 3 Reaction Chamber Top 4 Suction Cup 5 Airstone 6 Reaction Chamber Assembly 7 Airline Tubing 7 8 Air Pump 9 Inline Air Flow Valve 10 Check Valve PROTEIN SKIM...

Страница 7: ...wall between chambers 1 and 2 NOTE if skimmer is in correct position the right filtration cover will fit properly Collection Cup Assembly Figure C3 1 Place collection cup on top of reaction chamber P...

Страница 8: ...Add substrate rocks and d cor to the aquarium 2 Prepare saltwater for aquarium making sure water is at room temperature 3 Slowly add water to the aquarium Make sure to fill aquarium to the lower edge...

Страница 9: ...ith the refugium light to mount to BioCube HQI REFUGIUM SETUP AND REFUGIUM LIGHT INSTALLATION FIGURE C7 BioCube Filtration Stages Figures C8 C10 1 Water flows from aquarium into the surface and bottom...

Страница 10: ...Aqualight HQI ASSEMBLY AND SETUP INSTRUCTIONS AQUALIGHT HQI PARTS DIAGRAM 1 18 19 16 15 17 2 3 4 5 6 7 8 9 10 14 11 12 13 18 19...

Страница 11: ...ket Connection B with female connection knob using height adjustment knob 2 Screw height adjustment knob through Connection B and into Connection A 3 Adjust and secure connection Safety Precautions 1...

Страница 12: ...n connector on fixture 2 Attach cooling fan connector to cooling fan adaptor BALLAST AND COOLING FAN SETUP MALE FEMALE Double ended HQI Metal Halide Lamp Connector Double ended HQI Metal Halide Ballas...

Страница 13: ...HQI metal halide lamp with fingers as the oils may damage the lamp If contact is made with the lamp use a clean soft dry cloth to remove any fingerprints from the lamp before use LAMP REPLACEMENT Lam...

Страница 14: ...s BIOCUBE MAINTENANCE con t Filter Cartridge Overflow Tray Pump Housing Pump Impeller Ceramic Shaft Impeller Cover Sponge Filter FIGURE C12 FIGURE C13 FIGURE C14 t i l t u p Pull away WARNING 1 Make s...

Отзывы: