SAFETY:

1.   Turn off all switches and unplug all power 

cords from outlet or power source before 
performing maintenance.

2.  Make sure the unit is cool before handling.

Double-Ended HQI Metal Halide 
Lamp Replacement              
(Figures B10–B12)

1.   Remove the fixture from the aquarium.

2.  Place fixture on a non-abrasive flat surface 

with the bottom facing up.

3.  Remove the side panel (Figure B10).

 

NOTE:

 side end panel is located at the end     

of the fixture, opposite the cooling fan.

4.  Slide ventilation grill off of the fixture 

(Figure B10).

5.  Detach glass lens cover from the lamp 

holder by pushing the cover into the 
opposite end to free one side of the cover 
from the cover clamps (Figure B11).

6.  Use a soft cloth to grab one end of the 

lamp. Push the lamp into the opposite     
end to free one side of the lamp from       
the double-ended HQI metal halide socket 
(Figure B12).

7.  Gently lift the lamp up at an angle and 

remove the lamp (Figure B12).

8.  Carefully install replacement double-ended 

HQI metal halide lamp using a soft cloth.

9.  Replace all light fixture parts.

 

WARNING:

 Do not touch double-ended HQI 

metal halide lamp with fingers, as the oils 
may damage the lamp. If contact is made 
with the lamp, use a clean, soft, dry cloth to 
remove any fingerprints from the lamp 
before use.

LAMP REPLACEMENT

Lamp Holder

HQI Glass Lens Cover

Aqualight Hood

Ventilation

Grid

Side End

Panel

PRESS IN

PRESS IN

Use Soft

Cloth

LIFT UP

LIFT UP

Lamp Holder

FIGURE B10

FIGURE B11

FIGURE B12

Startup Operation

1.   Make sure all connections are completely 

attached and secure.

2.  Make sure that all switches are in the off 

position before plugging in power cords    
to power source

.

3.  Plug double-ended HQI metal halide ballast 

power cord into an outlet or power source 
and turn the switch on.

 

NOTE:

 It may take 5-10 minutes for 

double-ended HQI metal halide lamp          
to reach maximum light intensity.

 

CAUTION:

 When the double-ended HQI 

metal halide ballast is turned off, wait until 
the double-ended HQI metal halide lamp 
has completely cooled before turning 
ballast back on. Lamp may not turn on if not 
completely cooled.

4.  Verify that the lamp is lit and functioning 

properly.

5.  Plug cooling fan power cord into an outlet 

or power source and turn the switch on.

 

NOTE:

 Cooling fan must be on while      

lamp is on.

6.  Make sure cooling fans are on and are 

blowing freely across the unit.

OPERATION 

24

25

Содержание BioCube HQi

Страница 1: ...RRANTIES UNDER THIS LIMITED WARRANTY ALL SUCH WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY OCEANIC I...

Страница 2: ...tt 14 000K double ended metal halide Cooling Fans 38 mm 4 000 RPM Pump Flow Rate 243 gph 920 L H Page 4 Important Safety Instructions Page 6 Grounding Page 7 BioCube HQI Assembly and Setup Instruction...

Страница 3: ...ause algae growth 4 Keep aquarium in a well ventilated area away from a heating or cooling vent 5 Do not place near electronic components and systems i e TV stereo systems etc IMPORTANT SAFETY INSTRUC...

Страница 4: ...e like extending from the adapter must be fastened to a permanent ground such as a grounded outlet box 1 Plug temporary adapter into two pole outlet Figure A4 2 Insert screw through rigid ear on tempo...

Страница 5: ...ion Cover 2 Right Filtration Cover 3 Glass Canopy 4 Filter Cartridge 82105 5 Overflow Tray 6 Output Elbow Attachment 7 Flexible Tubing 8 Water Pump 82007 9 Output Discharge Nozzle 10 BioCube Glass Aqu...

Страница 6: ...tion 1 Collection Cup Lid 2 Collection Cup 3 Reaction Chamber Top 4 Suction Cup 5 Airstone 6 Reaction Chamber Assembly 7 Airline Tubing 7 8 Air Pump 9 Inline Air Flow Valve 10 Check Valve PROTEIN SKIM...

Страница 7: ...wall between chambers 1 and 2 NOTE if skimmer is in correct position the right filtration cover will fit properly Collection Cup Assembly Figure C3 1 Place collection cup on top of reaction chamber P...

Страница 8: ...Add substrate rocks and d cor to the aquarium 2 Prepare saltwater for aquarium making sure water is at room temperature 3 Slowly add water to the aquarium Make sure to fill aquarium to the lower edge...

Страница 9: ...ith the refugium light to mount to BioCube HQI REFUGIUM SETUP AND REFUGIUM LIGHT INSTALLATION FIGURE C7 BioCube Filtration Stages Figures C8 C10 1 Water flows from aquarium into the surface and bottom...

Страница 10: ...Aqualight HQI ASSEMBLY AND SETUP INSTRUCTIONS AQUALIGHT HQI PARTS DIAGRAM 1 18 19 16 15 17 2 3 4 5 6 7 8 9 10 14 11 12 13 18 19...

Страница 11: ...ket Connection B with female connection knob using height adjustment knob 2 Screw height adjustment knob through Connection B and into Connection A 3 Adjust and secure connection Safety Precautions 1...

Страница 12: ...n connector on fixture 2 Attach cooling fan connector to cooling fan adaptor BALLAST AND COOLING FAN SETUP MALE FEMALE Double ended HQI Metal Halide Lamp Connector Double ended HQI Metal Halide Ballas...

Страница 13: ...HQI metal halide lamp with fingers as the oils may damage the lamp If contact is made with the lamp use a clean soft dry cloth to remove any fingerprints from the lamp before use LAMP REPLACEMENT Lam...

Страница 14: ...s BIOCUBE MAINTENANCE con t Filter Cartridge Overflow Tray Pump Housing Pump Impeller Ceramic Shaft Impeller Cover Sponge Filter FIGURE C12 FIGURE C13 FIGURE C14 t i l t u p Pull away WARNING 1 Make s...

Отзывы: