The Manufacturer (OceanAire, Inc.) warrants to the 
original owner that the Product will be free from defects 
in material or workmanship for a period not to exceed 
one (1) year from date of installation. If upon 
examination by the Manufacturer the Product is shown 
to have a defect in material or workmanship during the 
warranty period, the Manufacturer will repair or replace, 
at its option, that part of the Product which is shown to 
be defective. 
 
The Manufacturer further warrants that the product's 
compressor-motor will be free from defects in materials 
and workmanship for five (5) years from the date of 
installation. If upon examination by the Manufacturer 
the Product is shown to have a defect in materials or 
workmanship during the warranty period, the 
Manufacturer will repair or replace, at its option, that 
Part of the Product which is shown to be defective. 
Electrical parts (such as relays, overloads, capacitors, 
etc...) and the sealed refrigeration system (condenser 
and evaporator) are included in the one year limited 
warranty , but not with the five year limited warranty of 
the compressor. This limited warranty does not apply: 
 

  a) if the Product has been subjected to     
      misuse or neglect, has been accidentally 
      or intentionally damaged, has not been 
      installed, maintained or operated in   
      accordance with the furnished  
      written instructions, or has been altered or  
      modified in any way. 
 
 b) to any expenses, including labor or  
     material, incurred during removal or  
      reinstallation of the Product.     
 
 c) to any workmanship of the installer of 
     the Product. 

T

his limited warranty is conditional upon: 

 
               (a) shipment, to the Manufacturer, 
                    of that part of the Product thought 
                  to be defective.  Goods can only  
                    be returned with prior written  
                    approval from the Manufacturer. 
                    All returns must be freight prepaid. 
 
               (b) determination, in the reasonable                                   
                    opinion of the Manufacturer  
                     that there exists a defect in                                           
                     material or workmanship. 
 
Repair or replacement of any  part under this Limited 
Warranty shall  not extend  the duration of the warranty  with  
respect to such  repaired or replaced  part beyond  the stated  
warranty period. 
 
THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER 
WARRANTIES, EITHER EXPRESS OR IMPLIED, AND 
ALL SUCH OTHER WARRANTIES, INCLUDING 
WITHOUT LIMITATION  IMPLIED WARRANTIES OF 
MERCHANTABILITY OR FITNESS FOR A  
PARTICULAR PURPOSE, ARE HEREBY  DISCLAIMED 
AND EXCLUDED FROM THIS LIMITED WARRANTY.  
IN  NO EVENT SHALL THE MANUFACTURER BE  
LIABLE IN ANY WAY FOR ANY CONSEQUENTIAL, 
SPECIAL, OR INCIDENTAL DAMAGES OF ANY 
NATURE WHATSOEVER, OR FOR ANY AMOUNTS IN 
EXCESS OF THE SELLING PRICE OF THE PRODUCT OR 
ANY PARTS THEREOF FOUND TO BE DEFECTIVE.  
THIS LIMITED WARRANTY GIVES THE ORIGINAL 
OWNER OF THE PRODUCT SPECIFIC LEGAL RIGHTS.  
YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY 
VARY BY EACH JURISDICTION. 
 
                 
 
                

23 

polarismanpg23 

Form PWC-ESM-5/02 

Содержание Polaris Series

Страница 1: ...R R polarismancover...

Страница 2: ...ondenser water is regulated by a refrigeration system head pressure actuated water regulating valve GENERAL REQUIREMENTS A MINIMUM WATER PRESSURE OF 20 PSIG IS REQUIRED to actuate the water regulating...

Страница 3: ...WC 24 1 2 PORTABLE VOLTAGE WATER COOLED SINGLE PHASE CAPACITY SELECTION CAPACITY SELECTION NUMBER CODE 10 10500 BTU HR 12 13780 BTU HR 18 18840 BTU HR 24 23950 BTU HR 36 36100 BTU HR 60 60100 BTU HR 2...

Страница 4: ...11 4 8 3 17 9 11 4 28 0 20 0 8 2 Compressor LRA 42 58 65 49 88 77 169 123 59 6 Evap CFM 2 300 400 600 810 1310 1310 1950 1950 1950 Evap Motor HP 1 15 1 15 1 5 1 3 1 2 1 2 1 1 1 Evap Motor Watts 200 20...

Страница 5: ...ge cold rolled steel with a platinum polyester powder coated finish that will compliment any decor The entire cabinet is insulated with a sound absorbant insu lation for cool quiet comfort The basepan...

Страница 6: ...ping against a 20 ft head and is con trolled by a float switch mechanism which turns the pump on when approximately 2 1 2 inches of water collects in the tank and automatically switches off when the t...

Страница 7: ...6012 NEMA 6 30R 208 230 VOLT SINGLE PHASE PAC6012 OAC6012 OACH6012 NEMA 6 50R 208 230 3 PHASE OAC PAC3632 OACH3632 OWC3632 PWC3632 NEMA L15 20R 208 230 3 PHASE PAC6032 OAC6032 OACH6032 PWC6032 OWC6032...

Страница 8: ...a hose kit avoid sharp corners hot water pipes and kinking to assure proper water flow of the supply and return lines HIGH PRESSURE WATER VALVE High pressure water regulating valves designed for use...

Страница 9: ...blower motor Thermostat Evaporator coil Fan motor capacitor Evaporator drain pan Drain hose Condensate pump Compressor Dry Base pan Casters Water valve High Pressure Switch Condenser Water Outlet Con...

Страница 10: ...f this manual Operating the unit on im proper voltage will void the warranty CAUTION the use of an extension cord must meet amperage requirement and have grounding type attachment plug and grounding t...

Страница 11: ...ine and supply valve 3 Connect shut off valve to T branch 4 Insert a 3 8 pipe nipple in discharge end of water shut off valve 5 Thread coupling onto 3 8 pipe nipple and secure An alternate installatio...

Страница 12: ...No No No No DDA 10 10 inch No No Yes Yes Yes No DDA 16 16 inch No No No No No Yes Maximum Equivalent Feet add 6 feet for each 90 elbow 25 25 50 50 50 100 Maximum E S P 15 15 25 25 25 50 11 Model Nozz...

Страница 13: ...beginning the cooling cycle Remember the setpoint must be lower than the room temperature for the unit to start The OUTDOOR and DAY NIGHT buttons are not used and do not ap ply to portable air conditi...

Страница 14: ...all models disconnect wire from control panel bend tinnerman clip retaining light and pull out Install new light reversing the procedure D CONDENSATE PUMP 1 Remove cabinet s left hand side panel 2 Rem...

Страница 15: ...y a qualified refrigeration serviceman PROBLEM THE ENTIRE UNIT DOES NOT RUN 1 CAUSE POWER INTERRUPTION REMEDY Check external power supply Look for blown fuses or tripped circuit breakers Reset or repl...

Страница 16: ...MEDY Locate leak and repair Evacuate unit and recharge 6 CAUSE Loose or defective wires FIXING Tug on wires to see if they will separate from connections 7 REASON Defective compressor REMEDY Check for...

Страница 17: ...ake sure unit is properly sized for load Add supplemental unit if required PROBLEM NOISY OPERATION 1 CAUSE Copper tubing vibrating REMEDY Adjust by bending slightly to firm position Segregate tubes to...

Страница 18: ...ertical height and horizontal drain line exceeds 20 ft of water pressure drop problems will occur PROBLEM THERMOSTAT LCD LIQUID CRYSTAL DISPLAY WINDOW DOES NOT ILLUMINATE 1 CAUSE Weak or dead batterie...

Страница 19: ...NSATE PUMP When servicing pump follow these steps 1 Make certain that the unit is disconnected from the power source before attempting to service or remove any component 2 Be sure the floats move free...

Страница 20: ...19 PIPING SCHEMATIC WATER COOLED AIR CONDITIONER polarismanpg19...

Страница 21: ...MINAL BLOCK THERMOSTAT COOLING ONLY EVAPORATOR FAN MOTOR HIGH LO EVAPORATOR FAN SWITCH LOW TERMINAL BLOCK COMPRESSOR CONTACTOR EVAPORATOR MOTOR CONTACTOR N R 24 Volt Coil 24 Volt Coil CONDENSATE PUMP...

Страница 22: ...3 COMPRESSOR CONTACTOR 24 Volt Coil EVAP FAN MOTOR 230 VOLT L1 L2 T1 T2 EVAP MOTOR CONTACTOR 24 Volt Coil CONDENSATE PUMP 230 Volt TERMINAL BLOCK HI LO FAN SWITCH HIGH LOW COM HIGH PRESSURE SWITCH RUN...

Страница 23: ...T1 T2 G Y W RH B O RC C Y G R TERMINAL BLOCK THERMOSTAT COOLING ONLY EVAPORATOR FAN MOTOR HIGH LO EVAPORATOR FAN SWITCH LOW COMPRESSOR CONTACTOR EVAPORATOR MOTOR CONTACTOR L3 R 24 Volt Coil 24 Volt C...

Страница 24: ...the furnished written instructions or has been altered or modified in any way b to any expenses including labor or material incurred during removal or reinstallation of the Product c to any workmansh...