Plug unit in and push FAN button once. This turns the evaporator fan blower on. To turn the blower off,
push the FAN button once again. This turns the fan blower off.
To change fan speeds, push the fan speed rocker switch up for high speed or down for low speed.
FAN ONLY
MODE
FAN
OUTDOOR
DAY/NIGHT
Robertshaw
72
WAIT 4 MINUTES
BEFORE RE-STARTING
polarismanpg12
12
COOLING CYCLE
To operate unit for cooling, push MODE button to dis-
play COOL in the window.
Push down arrow button multiple times to lower set
point to desired temperature.
The display will show the setpoint temperature for 5 sec-
onds, then it will return to room temperature display.
After a slight pause, the fan motor and compressor will
start, beginning the cooling cycle.
Remember, the setpoint must be lower than the room
temperature for the unit to start.
The OUTDOOR and DAY/NIGHT buttons are not used and do not ap-
ply to portable air conditioning.
GENERAL INFORMATION
This is a cooling only thermostat. Select the temperature you want by
pressing the
▲
or
▼
buttons. The word COOL and the temperature set-
point is displayed for 5 seconds.
To change display to Celsius, simultaneously press the
▲
and
▼
but-
tons. Press them again to change back to Fahrenheit.
No batteries are required. In the event of a power failure, when the
power is restored the thermostat will continue operating as if the power
had never been off.
Compressor short cycle protection is built-in to the thermostat. A 4 min-
ute time delay will protect the unit.
Electrical rating 24 to 30VAC
Control Range 60° to 88°
Temperature differential ± 1°
Anticipation Electronic
Manufacturer Robertshaw