58
E14
Dryer Heater/Fan/Thermostat Error
Do not run WM till enviromental conditions in
product specifications are met
Are environmental
conditions are OK?
Check if manual reset
thermostat is triggered by
pressing reset button.
Was it triggered?
NO
YES
Environmental conditions:
-Voltage range should be in as specified
in instruction book.
-Water pressure should be as specified
in instruction book.
-WM should be grounded properly.
-There should be enough ventilation
space from ground.
-Other environmental specifications and
requirements should be met which are
mentioned in instruction book of WM.
Check dryer fan connectors and
cables? Also check connectors on
dryer board. All connectors OK?
Check dryer fan referring to
componrnt control section 7.9? Is
fan OK?
Check dryer heater and thermostat
connectors & cables. Also check
connectors on dryer board. All
connectors OK?
Replace dryer heater group
Replace Cable Group
Replace dryer fan
Run an unloaded test drying
program inspecting the thermostats
and check if the issue reoccurs. Did
thermostat trigger again?
Check drying cycle components
(condenser, fan, heater group,
gasket, tub). Is the any obstacle
blocking the air flow?
Clean/remove the obstacle
This issue can happen during drying
cycles in case the appliance is
overloaded or fabric type may not be
appropriate as explained in IB or there
may be a momnetaryly blockage in air
ventilation which may cause the issue
Replace dryer card