![Ocean OWDI 9614 WT S Скачать руководство пользователя страница 54](http://html2.mh-extra.com/html/ocean/owdi-9614-wt-s/owdi-9614-wt-s_service-manual_5137961054.webp)
54
E05
Washer Heater or NTC Failure
Do not run WM till enviromental conditions in
product specifications are met
Refit loose sockets/connectors, replace cable
group if connectors/sockets are worn
Replace resistance
Are environmental
conditions are OK?
Check PCB socket
connections. Is thee any
loose socket/connector?
Similarly check resistance
and NTC connectors. Is it
loose?
Test resistance component as
explained in service manual. Is
resistance component OK?
Replace PCB
NO
YES
Environmental conditions:
-Voltage range should be in as specified
in instruction book.
-Water pressure should be as specified
in instruction book.
-WM should be grounded properly.
-There should be enough ventilation
space from ground.
-Other environmental specifications and
requirements should be met which are
mentioned in instruction book of WM.
Replace NTC
Test NTC component as
explained in service
manual. Is NTC
component OK?
Replace resistance
Disaasmble resistance and check
if the surface of the heater is
calcified. Is resistance surface
heavyly calcified?
Replace cable group
Redo same test by
PCB sockets? Is it
still OK?
Replace cable group
Redo same test by
PCB sockets? Is it
still OK?